CoChat

Standardization of Near-Infrared Spectrometric Instruments

Bouveresse, E., Hartmann, C., Massart, D. L., Last, I. R., Prebble, K. A. · 1996 · Analytical Chemistry
Cited by 246

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In this paper, two different approaches are studied for the standardization of near-infrared spectrometric instruments. The first is a simple method based on a univariate slope/bias correction of the predicted values. The second approach proposed is the much more sophisticated piecewise direct standardization (PDS) based on a multivariate correction of spectra. Both standardization methods are applied to three different data sets, and the results obtained are compared. In certain cases, the simple slope/bias correction approach yields results at least as good as those obtained by the PDS procedure. In other cases, the complex PDS procedure is required to obtain acceptable results. A diagnostic tool is developed in order to decide whether the simple slope/bias correction approach can be applied instead of PDS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9510595

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 246

Metadata

Authors
Bouveresse, E., Hartmann, C., Massart, D. L., Last, I. R., & Prebble, K. A.
Venue
Analytical Chemistry
Published
1996-01-01
Volume
68
Issue
6
Pages
982-990
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2069013297
Cited by
246
References
4
FWCI
11.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.