The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid Analyte Recognition in a Device Based on Optical Sensors and the Olfactory System
Abstract
We report here the development of a new vapor sensing device that is designed as an array of optically based chemosensors providing input to a pattern recognition system incorporating artificial neural networks. Distributed sensors providing inputs to an integrative circuit is a principle derived from studies of the vertebrate olfactory system. In the present device, primary chemosensing input is provided by an array of fiber-optic sensors. The individual fiber sensors, which are broadly yet differentially responsive, were constructed by immobilizing molecules of the fluorescent indicator dye Nile Red in polymer matrices of varying polarity, hydrophobicity, pore size, elasticity, and swelling tendency, creating unique sensing regions that interact differently with vapor molecules. The fluorescent signals obtained from each fiber sensor in response to 2-s applications of different analyte vapors have unique temporal characteristics. Using signals from the fiber array as inputs, artificial neural networks were trained to identify both single analytes and binary mixtures, as well as relative concentrations. Networks trained with integrated response data from the array or with temporal data from a single fiber made numerous errors in analyte identification across concentrations. However, when trained with temporal information from the fiber array, networks using "name" or "characteristic" output codes performed well in identifying test analytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corticotropin releasing activity of the new CRF is potentiated several times by vasopressin
Gillies, G. E., Linton, E. A., & Lowry, P. J. (1982) · Nature · doi:10.1038/299355a0 · Cited by 965
Cited by
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Cross-Reactive Chemical Sensor Arrays
Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000) · Chemical Reviews · doi:10.1021/cr980102w · Cited by 1,284
Self-citationSensing technologies for precision specialty crop production
Lee, W. S., Alchanatis, V., Yang, C., Hirafuji, M., Moshou, D., & Li, C. (2010) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2010.08.005 · Cited by 530
Acoustic Wave Microsensor Arrays for Vapor Sensing
Grate, J. W. (2000) · Chemical Reviews · doi:10.1021/cr980094j · Cited by 400
Diverse Applications of Electronic-Nose Technologies in Agriculture and Forestry
Wilson, A. (2013) · Sensors · doi:10.3390/s130202295 · Cited by 342
Metadata
- Authors
- White, J., Kauer, J. S., Dickinson, T. A., & Walt, D. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2191-2202
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2007782567
- Cited by
- 171
- References
- 1
- FWCI
- 11.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.