The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Cross-Reactive Chemical Sensor Arrays
Abstract
Conventional approaches to chemical sensors have \ntraditionally made use of a “lock-and-key” design, \nwherein a specific receptor is synthesized in order to \nstrongly and highly selectively bind the analyte of \ninterest.1-6 A related approach involves exploiting a \ngeneral physicochemical effect selectively toward a \nsingle analyte, such as the use of the ionic effect in \nthe construction of a pH electrode. In the first \napproach, selectivity is achieved through recognition \nof the analyte at the receptor site, and in the second, \nselectivity is achieved through the transduction \nprocess in which the method of detection dictates \nwhich species are sensed. Such approaches are appropriate \nwhen a specific target compound is to be \nidentified in the presence of controlled backgrounds \nand interferences. However, this type of approach \nrequires the synthesis of a separate, highly selective \nsensor for each analyte to be detected. In addition, \nthis type of approach is not particularly useful for \nanalyzing, classifying, or assigning human value \njudgments to the composition of complex vapor \nmixtures such as perfumes, beers, foods, mixtures of \nsolvents, etc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kirkpatrick, S. (1973) · Reviews of Modern Physics · doi:10.1103/revmodphys.45.574 · Cited by 5,260
A novel multigene family may encode odorant receptors: A molecular basis for odor recognition
Buck, L., & Axel, R. (1991) · Cell · doi:10.1016/0092-8674(91)90418-x · Cited by 4,987
Cited by
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Carbon Nanotube/Polythiophene Chemiresistive Sensors for Chemical Warfare Agents
Wang, F., Gu, H., & Swager, T. M. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710795k · Cited by 391
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Artificial sensing intelligence with silicon nanowires for ultraselective detection in the gas phase
Wang, B., Cancilla, J. C., Torrecilla, J. S., & Haick, H. (2014) · Nano Letters · doi:10.1021/nl404335p · Cited by 236
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Metadata
- Authors
- Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R.
- Venue
- Chemical Reviews
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-06-24
- Volume
- 100
- Issue
- 7
- Pages
- 2595-2626
- ISSN
- 0009-2665 (ISSN-L)
- 1520-6890
- OpenAlex
- W2091089517
- Cited by
- 1,284
- References
- 2
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cross-Reactive Chemical Sensor Arrays. https://app.cochat.ai/papers/10.1021/cr980102w
- The paper
- Albert, K. J., Lewis, N. S., Schauer, C. L., Sotzing, G. A., Stitzel, S. E., Vaid, T. P., & Walt, D. R. (2000). Cross-Reactive Chemical Sensor Arrays. Chemical Reviews. https://doi.org/10.1021/cr980102w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.