Ultrahigh-Speed Calculation of Isotope Distributions
The DOI matches its Crossref record.
Abstract
This paper introduces an ultrahigh-speed algorithm for calculating isotope distributions from molecular formulas, elemental isotopic masses, and elemental isotopic abundances. For a given set of input data (molecular formula, elemental isotopic masses, and elemental isotopic abundances), and assuming round-off error to be negilgible, the new algorithm rigorously produces isotope distributions whose mean and standard deviation are "correct" in the sense that an error-free algorithm would produce a distribution having the same mean and standard deviation. The peak heights are also "correct" in the sense that the height of each nominal isotope peak from the ultrahigh-speed calculation equals the integrated peak area of the corresponding nominal isotope peak from an exact calculation. As a consequence of these properties, the algorithm generally places isotope peaks within millidaltons of their true centroids. The method uses Fourier transform methods and relates closely to two other recently introduced algorithms. The suite of capabilities provided by these three algorithms is sufficient to solve an extremely wide range of problems requiring isotope distribution simulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- Rockwood A. L., 1995, Rapid Commun. Mass Spectrom., 9, 103, 10.1002/rcm.1290090122 · doi:10.1002/rcm.1290090122
- Rockwood A. L., 1995, Anal. Chem., 67, 2699, 10.1021/ac00111a031 · DOI · Paper page
- Rockwood A. L., 1996, Rapid Commun. Mass Spectrom., 10, 54, 10.1002/(SICI)1097-0231(19960115)10:1<54::AID-RCM444>3.0.CO;2-Z · DOI · Paper page
- Yergey J. A., 1983, Int. J. Mass Spectrom. Ion Phys., 52, 337, 10.1016/0020-7381(83)85053-0 · DOI · Paper page
- Brownawell J. A., 1982, J. Chem. Educ., 59, 663, 10.1021/ed059p663 · DOI
- Hsu C. S., 1984, Anal. Chem., 56, 1356, 10.1021/ac00272a035 · DOI
- Kubinyi H., 1991, Anal. Chim. Acta, 247, 107, 10.1016/S0003-2670(00)83059-7 · DOI
- Marshall A. G., 1990, Fourier Transforms in NMR, Optical, and Mass Spectrometry
Cited by
Overflow metabolism in Escherichia coli results from efficient proteome allocation
Basan, M., Hui, S., Okano, H., Zhang, Z., Shen, Y., Williamson, J. R., & Hwa, T. (2015) · Nature · doi:10.1038/nature15765 · Cited by 785
Kind, T., & Fiehn, O. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-234 · Cited by 637
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
SIRIUS: decomposing isotope patterns for metabolite identification
Böcker, S., Letzel, M. C., Lipták, Z., & Pervukhin, A. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btn603 · Cited by 354
Advances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Metadata
- Authors
- Rockwood, A. L., & Van Orden, S. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-07-01
- Volume
- 68
- Issue
- 13
- Pages
- 2027-2030
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044655708
- Cited by
- 122
- References
- 0
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh-Speed Calculation of Isotope Distributions. https://app.cochat.ai/papers/10.1021/ac951158i
- The paper
- Rockwood, A. L., & Van Orden, S. L. (1996). Ultrahigh-Speed Calculation of Isotope Distributions. Analytical Chemistry. https://doi.org/10.1021/ac951158i
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.