The DOI matches its Crossref record.
An Amperometric Microsensor for the Determination of H2S in Aquatic Environments
Abstract
A new amperometric microsensor for detection of dissolved H 2 S in aquatic environments was developed. The design of the microsensor is based on the same principle as the Clark-type oxygen microsensor. The sensor is equipped with a glass-coated platinum working electrode and a platinum guard electrode positioned in an outer glass casing (tip diameter 20−100 μm). Both working electrode and guard electrode were polarized at a fixed value in the range from +85 to + 150 mV with respect to a counter electrode. The outer casing is sealed with a thin silicone membrane and filled with a buffered electrolyte solution containing ferricyanide (K 3 [Fe(CN) 6 ]) as redox mediator. Hydrogen sulfide penetrates the silicone membrane and is oxidized by K 3 [Fe(CN) 6 ], resulting in the formation of elemental sulfur and ferrocyanide (K 4 [Fe(CN) 6 ]). The latter is electrochemically reoxidized at the exposed end of the platinum working electrode, thereby creating a current that is directly proportional to the dissolved H 2 S concentration at the sensor tip. The sensor was characterized and calibrated in a flow-through cell combined with a coulometric sulfide generator. Difficult studies including the determination of H 2 S with high spatial and temporal resolution seem to be possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electric currents couple spatially separated biogeochemical processes in marine sediment
Nielsen, L. P., Risgaard-Petersen, N., Fossing, H., Christensen, P. B., & Sayama, M. (2010) · Nature · doi:10.1038/nature08790 · Cited by 567
BORUM, J., PEDERSEN, O., GREVE, T. M., FRANKOVICH, T. A., ZIEMAN, J. C., FOURQUREAN, J. W., & MADDEN, C. J. (2005) · Journal of Ecology · doi:10.1111/j.1365-2745.2004.00943.x · Cited by 296
A nitrite microsensor for profiling environmental biofilms
De Beer, D., Schramm, A., Santegoeds, C. M., & Kuhl, M. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.3.973-977.1997 · Cited by 266
Sulphide intrusion in eelgrass ( Zostera marina L.)
PEDERSEN, O., BINZER, T., & BORUM, J. (2004) · Plant, Cell & Environment · doi:10.1111/j.1365-3040.2004.01173.x · Cited by 248
Hydrogen Sulfide as an Oxygen Sensor
Olson, K. R. (2015) · Antioxidants & Redox Signaling · doi:10.1089/ars.2014.5930 · Cited by 144
Metadata
- Authors
- Jeroschewski, P., Steuckart, C., & Kühl, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 68
- Issue
- 24
- Pages
- 4351-4357
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1985667871
- Cited by
- 352
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Amperometric Microsensor for the Determination of H2S in Aquatic Environments. https://app.cochat.ai/papers/10.1021/ac960091b
- The paper
- Jeroschewski, P., Steuckart, C., & Kühl, M. (1996). An Amperometric Microsensor for the Determination of H2S in Aquatic Environments. Analytical Chemistry. https://doi.org/10.1021/ac960091b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.