Miniaturized Biosensors Employing Electropolymerized Permselective Films and Their Use for Creatinine Assays in Human Serum
The DOI matches its Crossref record.
Abstract
Miniaturized, disposable amperometric biosensors for determination of creatinine in human serum are described. The base electrodes are fabricated using micro-electronics techniques, to build a multilayer film structure on a polyimide foil. By using a thin electropolymerized film of poly(1,3-diaminobenzene), the electrochemical interferences from ascorbate, urate, acetaminophen, and other oxidizable species are greatly diminished. The multienzyme system (creatininase, creatinase, sarcosine oxidase) is immobilized on top of the permselective layer using cross-linking of the proteins with glutaraldehyde. The electropolymerization conditions for obtaining almost ideal permselectivity of the inner layer are defined, as well as the optimal enzyme layer preparation. A composite polymeric outer membrane [Nafion + poly-(2-hydroxy-ethyl methacrylate) is used for diffusion control and to protect the enzyme layer from fouling. The reagentless planar sensors for creatinine and creatine have fast response time (t95 = 1 min), linear response up to 1.2 mM in batch-type and 2.0 mM in flow injection analysis and a detection limit of 10-20 muM. They are applied in a differential setup for creatinine assay in control and hospital human serum samples and are suitable for incorporation in a portable analyzer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Creatine and Creatinine Metabolism
Wyss, M., & Kaddurah-Daouk, R. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.3.1107 · Cited by 2,950
Polymers in sensor applications
Adhikari, B., & Majumdar, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.03.002 · Cited by 1,181
Novel Multifunctional Polymers from Aromatic Diamines by Oxidative Polymerizations
Li, X.-G., Huang, M.-R., Duan, W., & Yang, Y.-L. (2002) · Chemical Reviews · doi:10.1021/cr010423z · Cited by 682
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
Metadata
- Authors
- Mǎdǎraş, M. B., & Buck, R. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-11-01
- Volume
- 68
- Issue
- 21
- Pages
- 3832-3839
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2088025801
- Cited by
- 129
- References
- 0
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Miniaturized Biosensors Employing Electropolymerized Permselective Films and Their Use for Creatinine Assays in Human Serum. https://app.cochat.ai/papers/10.1021/ac960239r
- The paper
- Mǎdǎraş, M. B., & Buck, R. P. (1996). Miniaturized Biosensors Employing Electropolymerized Permselective Films and Their Use for Creatinine Assays in Human Serum. Analytical Chemistry. https://doi.org/10.1021/ac960239r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.