Calibration of Solid Phase Microextraction for Air Analyses Based on Physical Chemical Properties of the Coating
Abstract
Solid phase microextraction (SPME) with poly(dimethylsiloxane) (PDMS) is used to sample dynamic hydrocarbon standard gas mixtures with calibration for temperature, relative humidity, gas velocities, and gas concentrations. Equilibration times were found to vary from 15 to 450 s depending on the compound. Relative humidity greater than 90% at various temperatures was found to decrease analyte mass loading by 10%. Investigation of linearity with PDMS showed all of the analytes had a linear relationship between mass loaded at equilibrium and the gas concentrations studied. Analyte detection limits are better than those for conventional grab sampling (concentration with adsorbent tubes and analysis by gas chromatography and flame ionization detection). Partition coefficients ( K ) were established at various temperatures, yielding a linear relationship between log K and T - 1 . The linear expression has a slope that is a function of the gas constant and the analyte heat of vaporization (Δ H v ) and a y -intercept that is a combination of terms among which include the gas constant, analyte Δ H v, and activity coefficient; therefore, K values can be estimated using literature Δ H v and ascertained at temperatures for which a K was not determined. This removes the restriction that calibration and air sampling must be carried out at the same temperature. A comparison of PDMS (100 μm) fiber lengths ( n = 13) revealed an average fiber length of 1.02 ± 0.03 cm. An interfiber estimation of method precision ( n = 10) yielded less than 9% RSD for all the test analytes. When a correction for fiber lengths was applied, the differences between the means of area counts for the individual fibers was statistically insignificant. SPME was successfully field tested as a grab sampler and an integrated sampler to analyze air at an industrial site, with excellent agreement to traditional air sampling methods. This work suggests that ambient and industrial air sampling with SPME is possible with essentially no calibration of the sampling device. It is only necessary to know the analyte's K to the fiber at various temperatures which is based on defined and empirically determinable physical constants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Self-citationSolid-phase microextraction: a promising technique for sample preparation in environmental analysis
de Fátima Alpendurada, M. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00453-2 · Cited by 449
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Self-citation(1999) · CRC Press eBooks · doi:10.1201/9780367803223 · Cited by 268
Metadata
- Authors
- Martos, P. A., & Pawliszyn, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-01-01
- Volume
- 69
- Issue
- 2
- Pages
- 206-215
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1991867671
- Cited by
- 189
- References
- 0
- FWCI
- 13.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.