The DOI matches its Crossref record.
Detection of High Molecular Weight Narrow Polydisperse Polymers up to 1.5 Million Daltons by MALDI Mass Spectrometry
Abstract
The detection of very high molecular weight narrow polydisperse poly(styrene) samples by MALDI time-of-flight mass spectrometry is reported. It is shown that accurate molecular weight determinations of samples up to 1 million can be achieved very rapidly from the singly charged polymeric species. For a poly(styrene) with a molecular weight of approximately 1.5 million, signals corresponding to the multiply charged ions of the principal distribution are observed. The molecular weights obtained by MALDI are in good agreement with classical molecular weight determination techniques. all-trans-Retinoic acid was used as the organic matrix for the laser desorption procedure, and the samples were analyzed as their silver cation adducts. This work demonstrates that, with proper matrix selection and sample preparation, MALDI can be a very useful tool for high molecular weight polymer sample analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maldi time-of-flight mass spectrometry of synthetic polymers
Nielen, M. W. F. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:5<309::aid-mas2>3.0.co;2-l · Cited by 566
Characterization of synthetic polymers by MALDI-MS
Montaudo, G., Samperi, F., & Montaudo, M. S. (2006) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2005.12.001 · Cited by 446
Imaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Metadata
- Authors
- Schriemer, D. C., & Li, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-09-01
- Volume
- 68
- Issue
- 17
- Pages
- 2721-2725
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048795280
- Cited by
- 243
- References
- 0
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.