The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Solid-Phase Microextraction for the Analysis of Human Breath
Abstract
Solid-phase microextraction (SPME) has been applied to the quantitative determination of ethanol, acetone, and isoprene in human breath. The method involves extraction and preconcentration with a fused silica fiber coated with a polymeric stationary phase, desorption at 200 degrees C, and assay by gas chromatography/mass spectrometry. Three different fiber coatings have been evaluated with regard to sensitivity, linear range, precision, and detection limits. Typical RSD values in the range 2%-6% could be obtained, depending on the fiber coating and the compound investigated. The calibration curves for the compounds are reproducible and linear over the concentration ranges found in human breath samples. The method is capable of detecting concentrations of acetone and isoprene reported for healthy subjects. The influence of temperature and humidity on the extraction process has been studied in detail. A linear relationship between log K versus 1/T allows the calibration of the method for any given temperature. The device is portable, economical, and easy to use in patient sampling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics for analytical chemistry
Nielsen, E. (1987) · Forensic Science International · doi:10.1016/0379-0738(87)90151-4 · Cited by 1,028
Dynamics of organic compound extraction from water using liquid-coated fused silica fibers
Louch, D., Motlagh, S., & Pawliszyn, J. (1992) · Analytical Chemistry · doi:10.1021/ac00034a020 · Cited by 603
Self-citationThe diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
Volatile organic compounds in exhaled air from patients with lung cancer.
Gordon, S. M., Szidon, J. P., Krotoszynski, B. K., Gibbons, R. D., & O'Neill, H. J. (1985) · Clinical Chemistry · doi:10.1093/clinchem/31.8.1278 · Cited by 366
Chai, M., & Pawliszyn, J. (1995) · Environmental Science & Technology · doi:10.1021/es00003a017 · Cited by 251
Self-citationHigh breath pentane concentrations during acute myocardial infarction
Weitz, Z., Birnbaum, A. J., Skosey, J. L., Sobotka, P. A., & Zarling, E. J. (1991) · The Lancet · doi:10.1016/0140-6736(91)91569-g · Cited by 128
Practical HPLC Method Development
(1994) · Analytical Chemistry · doi:10.1021/ac00089a717 · Cited by 61
Evidence of brain methyltransferase inhibition and early brain involvement in HIV-positive patients
Keating, J. N., Trimble, K. C., Mulcahy, F., et al. (1991) · The Lancet · doi:10.1016/0140-6736(91)91570-k · Cited by 60
Lawrence, G. D., & Cohen, G. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90282-2 · Cited by 59
Periago, J. F., Prado, C., Ibarra, I., & Tortosa, J. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)83046-u · Cited by 21
Cited by
Metabolomics: Current analytical platforms and methodologies
(2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.021 · Cited by 1,192
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Evolution of solid-phase microextraction technology
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00535-5 · Cited by 787
Self-citationNoninvasive detection of lung cancer by analysis of exhaled breath
Bajtarevic, A., Ager, C., Pienz, M., Klieber, M., Schwarz, K., Ligor, M., Ligor, T., Filipiak, W., Denz, H., Fiegl, M., et al. (2009) · BMC Cancer · doi:10.1186/1471-2407-9-348 · Cited by 597
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Metadata
- Authors
- Grote, C., & Pawliszyn, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-02-01
- Volume
- 69
- Issue
- 4
- Pages
- 587-596
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2044044827
- Cited by
- 300
- References
- 10
- FWCI
- 16.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.