The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Analysis of Oligonucleotides by HPLC−Electrospray Ionization Mass Spectrometry
Abstract
A new interface procedure has been developed that allows, for the first time, the high-efficiency analysis of synthetic oligonucleotides up to 75 bases by reversed-phase HPLC and on-line electrospray ionization mass spectrometry. For oligonucleotides up to 30 bases in length, single-base resolution can be obtained with low levels of cation adduct formation in the negative ion electrospray mass spectra. A key part of the method uses 1,1,1,3,3,3-hexafluoro-2-propanol as an additive to the HPLC mobile phase, adjusted to pH 7.0 with triethylamine. This novel additive results in both good HPLC separation and efficient electrospray ionization. The broad potential of this new method is demonstrated for synthetic homopolymers of thymidine (PolyT), fragments based on the pBR322 plasmid sequence, and phosphorothioate ester antisense oligonucleotides. This approach will be of particular utility for the characterization of DNA probes and PCR primers and quality control of antisense compounds such as phosphorothioates and their metabolites, as well as of materials used in clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Utility of organic bases for improved electrospray mass spectrometry of oligonucleotides
Greig, M., & Griffey, R. H. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290090121 · Cited by 187
Suppression of Philadelphia1 leukemia cell growth in mice by BCR-ABL antisense oligodeoxynucleotide.
Skorski, T., Nieborowska-Skorska, M., Nicolaides, N. C., Szczylik, C., Iversen, P., Iozzo, R. V., Zon, G., & Calabretta, B. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.10.4504 · Cited by 171
Characterization of oligonucleotides and nucleic acids by mass spectrometry
Limbach, P. A., Crain, P. F., & McCloskey, J. A. (1995) · Current Opinion in Biotechnology · doi:10.1016/0958-1669(95)80015-8 · Cited by 101
Naito, Y., Ishikawa, K., Koga, Y., Tsuneyoshi, T., Terunuma, H., & Arakawa, R. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091504 · Cited by 52
Rapid analysis of biopolymers on modified non-porous polystyrene-divinylbenzene particles
Huber, C. G., Oefner, P. J., & Bonn, G. K. (1993) · Chromatographia · doi:10.1007/bf02274118 · Cited by 44
Cited by
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Premstaller, A., Oberacher, H., & Huber, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac000283d · Cited by 283
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Label-free analysis of mRNA capping efficiency using RNase H probes and LC-MS
Beverly, M., Dell, A., Parmar, P., & Houghton, L. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9605-x · Cited by 83
Cao, H., Hearst, J. E., Corash, L., & Wang, Y. (2008) · Analytical Chemistry · doi:10.1021/ac7023969 · Cited by 70
Metadata
- Authors
- Apffel, A., Chakel, J. A., Fischer, S., Lichtenwalter, K., & Hancock, W. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-04-01
- Volume
- 69
- Issue
- 7
- Pages
- 1320-1325
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1970070502
- Cited by
- 398
- References
- 5
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of Oligonucleotides by HPLC−Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac960916h
- The paper
- Apffel, A., Chakel, J. A., Fischer, S., Lichtenwalter, K., & Hancock, W. S. (1997). Analysis of Oligonucleotides by HPLC−Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac960916h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.