A Gated Electrostatic Ion Trap To Repetitiously Measure the Charge and m/z of Large Electrospray Ions
Abstract
The design and operation of a new type of ion trap provides a way to measure mass, charge, and velocity of large individual electrospray ions (>1 MDa, >250 charges) repeatedly during the time the ion is trapped. The trap consists of an image charge detection tube mounted between two ion mirrors. The mirrors are sets of parallel electrodes drilled with holes aligned with the bore of the detector tube. The device relies on voltages applied to the electrodes to establish symmetrically opposing ion focusing mirrors for the purpose of cycling ions through the charge detection tube many times. This design does not use magnetic or radio frequency fields to trap ions. Gating one of the mirrors to 0 V while maintaining voltages appropriate for reflecting ions on the opposite mirror allows an ion to pass through the holes in the mirror and enter the detector tube. A low-noise charge-sensitive amplifier, connected to the tube, reproduces the image charge of individual ions as they pass through the detector tube. When a highly charged electrospray ion enters the detector tube, its image charge triggers a circuit that enables the entrance electrodes, thus closing the electrostatic gate to the trap. Ion mass is calculated from simultaneous measurements of ion charge and velocity every time an ion passes through the detector. Individual ions have been trapped for as long as about 10 ms, during which time they cycled 450 times through the detector tube. At this level of trapping time, a theoretical precision for charge measurement as small as about two electrons rms can be achieved for 200 eV/charge ions carrying more than 250 charges. The operation of the system is demonstrated by trapping 2.88 MDa ions of DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Kafader, J. O., Melani, R. D., Durbin, K. R., Ikwuagwu, B., Early, B. P., Fellers, R. T., Beu, S. C., Zabrouskov, V., Makarov, A. A., Maze, J. T., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-0764-5 · Cited by 197
Resolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
STORI Plots Enable Accurate Tracking of Individual Ion Signals
Kafader, J. O., Beu, S. C., Early, B. P., Melani, R. D., Durbin, K. R., Zabrouskov, V., Makarov, A. A., Maze, J. T., Shinholt, D. L., Yip, P. F., et al. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02309-0 · Cited by 85
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Kafader, J. O., Durbin, K. R., Melani, R. D., Des Soye, B. J., Schachner, L. F., Senko, M. W., Compton, P. D., & Kelleher, N. L. (2020) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00797 · Cited by 76
Metadata
- Authors
- Benner, W. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-10-01
- Volume
- 69
- Issue
- 20
- Pages
- 4162-4168
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2031012119
- Cited by
- 203
- References
- 0
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.