The DOI matches its Crossref record.
Microchip Device for Performing Enzyme Assays
Abstract
An automated enzyme assay was performed within a microfabricated channel network. Precise concentrations of substrate, enzyme, and inhibitor were mixed in nanoliter volumes using electrokinetic flow. Reagent dilution and mixing were controlled by regulating the applied potential at the terminus of each channel, using voltages derived from an equivalent circuit model of the microchip. The enzyme beta-galactosidase (beta-Gal) was assayed using resorufin beta-D-galactopyranoside (RBG), a substrate that is hydrolyzed to resorufin, a fluorescent product. Reaction kinetics were obtained by varying the concentration of substrate on-chip and monitoring the production of resorufin using laser-induced fluorescence. Derived Michaelis--Menten constants compared well between an on-chip and a conventional enzyme assay. Bias in the derived K(m) and kcat was primarily due to the limited solubility of RBG and the associated lack of measurements at substrate concentrations exceeding the K(m). A Ki of 8 microM for the inhibitor phenylethyl beta-D-thiogalactoside (PETG) was determined from plots of initial rate versus substrate concentration obtained at three concentrations of PETG. The relative inhibition of beta-Gal by lactose, p-hydroxymercuribenzoic acid, and PETG was determined by varying the inhibitor concentration with constant enzyme and substrate concentration. An enzyme assay performed on the microchip within a 20-min period required only 120 pg of enzyme and 7.5 ng of substrate, reducing the amount of reagent consumed by 4 orders of magnitude over a conventional assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
New assay technologies for high-throughput screening
Silverman, L., Campbell, R., & Broach, J. R. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80015-x · Cited by 151
Metadata
- Authors
- Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 69
- Issue
- 17
- Pages
- 3407-3412
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2037826246
- Cited by
- 383
- References
- 0
- FWCI
- 18.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microchip Device for Performing Enzyme Assays. https://app.cochat.ai/papers/10.1021/ac970192p
- The paper
- Hadd, A. G., Raymond, D. E., Halliwell, J. W., Jacobson, S. C., & Ramsey, J. M. (1997). Microchip Device for Performing Enzyme Assays. Analytical Chemistry. https://doi.org/10.1021/ac970192p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.