Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 681

The DOI matches its Crossref record.

Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe

He, Y., Lee, H. K.·1997·Analytical Chemistry

Abstract

Two modes of liquid-phase microextraction (LPME) were developed for capillary gas chromatography. Both methodologies, i.e., static LPME and dynamic LPME, involve the use of very small amounts of organic solvent (<2 μL) in a conventional microsyringe. The performance of the two techniques is demonstrated in the determination of two chlorobenzenes extracted into a single drop of toluene by the use of a 10-μL syringe. Static LPME provided some enrichment (∼12-fold), good reproducibility (9.7%), and simplicity but suffered relatively long extraction time (15 min). Dynamic LPME provided higher (∼27-fold) enrichment within much shorter extraction time (∼3 min), and relatively poorer precision (12.8%), primarily due to repeated manual manipulation. Both methods allow the direct transfer of extracted analytes into a gas chromatograph.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac970242q

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 19

  1. Karlberg B., 1978, Anal. Chim. Acta, 98, 7, 10.1016/S0003-2670(01)83231-1 · DOI
  2. Kraak J. C., 1983, Trends Anal. Chem., 2, 187, 10.1016/0165-9936(83)80013-2 · doi:10.1016/0165-9936(83)80013-2
  3. Onuska F. I., 1989, J. High Resolut. Chromatogr., 12, 11
  4. Hagen D. R., 1990, Anal. Chim. Acta, 236, 164, 10.1016/S0003-2670(00)83309-7 · DOI · Paper page
  5. Arthur C. L., 1992, LC-GC, 10, 661
  6. Arthur C. L., 1990, Anal. Chem., 62, 2148, 10.1021/ac00218a019 · DOI · Paper page
  7. Potter D. W., 1994, Environ. Sci. Technol., 28, 305, 10.1021/es00051a017 · DOI · Paper page
  8. Murray D. A. J., 1979, J. Chromatogr., 177, 140
  9. Cantwell F. F., 1996, Anal. Chem., 68, 2240
  10. Rideal, E. K.An introduction to surface chemistry; Cambridge University Press: Cambridge, U.K., 1930; Chapter 1, p 13.
  11. Fowlis, I. A.Gas Chromatography, 2nd ed.; Greenwich University Press, John Wiley & Sons: New York, 1995; Chapter 5, p 109.
  12. Laddha G., 1976, Transport Phenomena in Liquid Extraction
  13. Cussler, E. L.Diffusion: Mass Transfer in Fluid Systems; Cambridge University Press: Cambridge, U.K., 1984; Chapters 1, 2, 9, and 11.
  14. Liu S., 1995, Anal. Chem., 67, 2049
  15. Liu H., 1995, Anal. Chem., 67, 4228
  16. Jeannot M. A., 1997, Anal. Chem., 69, 239
  17. Liu H., 1994, Anal. Chim. Acta, 288, 245
  18. Liu H., 1995, Process Control Qual., 7, 202
  19. Chen J., 1995, Anal. Chem., 67, 2538

Cited by

Metadata

Authors
He, Y., & Lee, H. K.
Venue
Analytical Chemistry
Published
1997-11-01
Volume
69
Issue
22
Pages
4634-4640
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2086924034
Cited by
681
References
0
FWCI
3.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.