Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 640

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Integrated Capillary Electrophoresis on Flexible Silicone Microdevices: Analysis of DNA Restriction Fragments and Detection of Single DNA Molecules on Microchips

Effenhauser, Carlo S., Bruin, Gerard J. M., Paulus, Aran, Ehrat, Markus·1997·Analytical Chemistry

Abstract

Microchips for integrated capillary electrophoresis systems were produced by molding a poly(dimethylsiloxane) (PDMS) silicone elastomer against a microfabricated master. The good adhesion of the PDMS devices on clean planar surfaces allows for a simple and inexpensive generation of networks of sealed microchannels, thus removing the constraints of elaborate bonding procedures. The performance of the devices is demonstrated with both fast separations of φX-174/HaeIII DNA restriction fragments labeled with the intercalating dye YOYO-1 and fluorescently labeled peptides. Detection limits in the order of a few zeptomoles (10(-)(21) mol) have been achieved for each injected DNA fragment, corresponding to a mass detection limit of ∼2 fg for the 603 base pair fragment. Single λ-DNA molecules intercalated with YOYO-1 at a base pair-to-dye ratio of 10:1 could be detected with an uncomplicated laser-induced fluorescence detection setup. High single-molecule detection efficiency (>50%) was achieved under electrophoretically controlled mass transport conditions in PDMS microchannels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9703919

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 640

Metadata

Authors
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M.
Venue
Analytical Chemistry
Published
1997-09-01
Volume
69
Issue
17
Pages
3451-3457
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2091684085
Cited by
640
References
1
FWCI
32.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.