The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
Abstract
A number of polydimethysiloxane (PDMS) bonding techniques have been reported in the literature over the last several years as the focus on multilayer PDMS microfluidic devices has increased. Oxygen plasma bonding, despite cost, additional fabrication time and inconsistent bonding results, has remained a widely used method for bonding PDMS layers. A comparative study of four rapid, inexpensive alternative PDMS–PDMS bonding approaches was undertaken to determine relative bond strength. These include corona discharge, partial curing, cross-linker variation and uncured PDMS adhesive. Partial curing and uncured PDMS adhesive demonstrated a considerable improvement in bond strength and consistency by retaining average bond strengths of over 600 kPa, which was more than double the average bond strength of oxygen plasma. A description of each technique and their performance relative to oxygen plasma bonding is included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
PDMS bonding by means of a portable, low-cost corona system
Haubert, K., Drier, T., & Beebe, D. (2006) · Lab on a Chip · doi:10.1039/b610567j · Cited by 307
Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
A PDMS-based gas permeation pump for on-chip fluid handling in microfluidic devices
Eddings, M. A., & Gale, B. K. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/11/021 · Cited by 147
Self-citationA disposable, dead volume-free and leak-free in-plane PDMS microvalve
Go, J. S., & Shoji, S. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.12.028 · Cited by 85
Samel, B., Chowdhury, M. K., & Stemme, G. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/8/038 · Cited by 68
Cited by
Bend, stretch, and touch: Locating a finger on an actively deformed transparent sensor array
Sarwar, M. S., Dobashi, Y., Preston, C., Wyss, J. K. M., Mirabbasi, S., & Madden, J. D. W. (2017) · Science Advances · doi:10.1126/sciadv.1602200 · Cited by 370
Tsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Flexible Plasmonics on Unconventional and Nonplanar Substrates
Aksu, S., Huang, M., Artar, A., Yanik, A. A., Selvarasah, S., Dokmeci, M. R., & Altug, H. (2011) · Advanced Materials · doi:10.1002/adma.201102430 · Cited by 253
Electronics with shape actuation for minimally invasive spinal cord stimulation
Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G. (2021) · Science Advances · doi:10.1126/sciadv.abg7833 · Cited by 75
Metadata
- Authors
- Eddings, M. A., Johnson, M. A., & Gale, B. K.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2008-04-25
- Volume
- 18
- Issue
- 6
- Pages
- 067001
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2039001850
- Cited by
- 567
- References
- 10
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining the optimal PDMS–PDMS bonding technique for microfluidic devices. https://app.cochat.ai/papers/10.1088/0960-1317/18/6/067001
- The paper
- Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008). Determining the optimal PDMS–PDMS bonding technique for microfluidic devices. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/18/6/067001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.