A Strategy for Rapid, High-Confidence Protein Identification
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A procedure is described for rapid, high-confidence identification of proteins using matrix-assisted laser desorption/ionization tandem ion trap mass spectrometry in conjunction with a genome database searching strategy. The procedure involves excision of copper-stained bands or spots from electrophoretic gels, in-gel trypsin digestion of the proteins, single-stage mass spectrometric analysis of the resultant mixture of tryptic peptides, followed by tandem ion trap mass spectrometric analysis of selected individual peptides, and database searching of the relevant genomic database using the program PepFrag. The scheme provides sensitive, real-time protein identification as well as facile identification of modifications. A single operator can unambiguously identify 5-10 proteins/day from an organism whose genome is known at a level of > 0.5 pmol of protein loaded on a gel. The utility of the technique was demonstrated by the identification and characterization of a band from a human HTLV-I preparation and 11 different proteins from a yeast RNA polymerase II C-terminal repeat domain-affinity preparation. The technology has great potential for postgenome biological science, where it promises to facilitate the dissection and anatomy of macromolecular assemblages, the definition of disease state markers, and the investigation of protein targets in biological processes such as the cell cycle and signal transduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seiki, M., Hattori, S., Hirayama, Y., & Yoshida, M. (1983) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.80.12.3618 · Cited by 1,525
Cited by
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
The Yeast Nuclear Pore Complex
Rout, M. P., Aitchison, J. D., Suprapto, A., Hjertaas, K., Zhao, Y., & Chait, B. T. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.148.4.635 · Cited by 1,400
Self-citationMass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Molecular Biologist's Guide to Proteomics
Graves, P. R., & Haystead, T. A. J. (2002) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.66.1.39-63.2002 · Cited by 691
Both corepressor proteins SMRT and N‐CoR exist in large protein complexes containing HDAC3
Li, J., Wang, J., Wang, J., Nawaz, Z., Liu, J. M., Qin, J., & Wong, J. (2000) · The EMBO Journal · doi:10.1093/emboj/19.16.4342 · Cited by 629
Self-citation
Metadata
- Authors
- Qin, J., Fenyö, D., Zhao, Y., Hall, W. W., Chao, D. M., Wilson, C. J., Young, R. A., & Chait, B. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-10-01
- Volume
- 69
- Issue
- 19
- Pages
- 3995-4001
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1974909424
- Cited by
- 90
- References
- 1
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.