Selective Detection of Deoxyribonucleic Acid at Ultralow Concentrations by SERRS
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Genetic research programs such as the human genome project have demonstrated the need for selective detection of nucleic acids at ultralow concentrations (McKusik, V. A. FASEB J. 1991, 5, 12−20. Cui, X.; et al. Proc. Natl. Acad. Sci. U.S.A. 1989, 89, 9389−9393). Current detection techniques require amplification of the genetic material by the polymerase chain reaction (PCR) and detection of the amplified product by fluorescence. A new reliable method for DNA detection has been developed based on adsorption of DNA on colloidal silver and subsequent signal detection using surface-enhanced resonance Raman scattering (SERRS). It uses specifically designed primers and can be applied directly to genetic analysis. Improved surface and aggregation chemistry, utilizing modified DNA and a novel aggregating agent, has resulted in acceptable reproducibility for biological detection. DNA was detected down to 8 × 10 -13 M, which equates to less than one molecule in the interrogation volume at any one time, and an RSD of 10% was obtained. The increased sensitivity compared to fluorescence circumvents the need for an amplification step, and much greater selectivity is obtained due to the sharp vibrational spectra observed, thus reducing the need for separation procedures. The method is potentially sensitive enough to eliminate the need for time-consuming amplification steps and provide a new dimension to labeling chemistry and multiplex analysis of DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Guerrini, L., & Graham, D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35118h · Cited by 441
Self-citationSERS Microscopy: Nanoparticle Probes and Biomedical Applications
Schlücker, S. (2009) · ChemPhysChem · doi:10.1002/cphc.200900119 · Cited by 372
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Review of Surface Enhanced Raman Scattering Applications in Forensic Science
Muehlethaler, C., Leona, M., & Lombardi, J. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04131 · Cited by 313
Metadata
- Authors
- Graham, D., Smith, W. E., Linacre, A. M. T., Munro, C. H., Watson, N. D., & White, P. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-11-01
- Volume
- 69
- Issue
- 22
- Pages
- 4703-4707
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2079867423
- Cited by
- 157
- References
- 1
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective Detection of Deoxyribonucleic Acid at Ultralow Concentrations by SERRS. https://app.cochat.ai/papers/10.1021/ac970657b
- The paper
- Graham, D., Smith, W. E., Linacre, A. M. T., Munro, C. H., Watson, N. D., & White, P. C. (1997). Selective Detection of Deoxyribonucleic Acid at Ultralow Concentrations by SERRS. Analytical Chemistry. https://doi.org/10.1021/ac970657b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.