The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography
Abstract
In “comprehensive” two-dimensional liquid chromatography, the column effluent from the first separation system (the first dimension) is sequentially sampled by the second dimension separation system. The total analysis time is largely determined by the speed of the second dimension separation system; the most retained component must elute before the least retained component of the next second dimension separation. Optimization of multidimensional separation systems requires that one understand the relationship between system resolution and the number of second dimension samples across a first dimension peak. In this paper, we study the theoretical and experimental aspects of this sampling process. To obtain high two-dimensional resolution, each peak in the first dimension should be sampled at least three times into the second dimension when the sampling is in-phase. If the sampling is maximally out of phase, there should be at least four samples per peak for high-fidelity separation. The sensitivity of the resolution with respect to the sampling phase is discussed in detail and shown to be insignificant when four or greater samples are taken across the first dimension peak width. These results suggest optimal criteria for method development with multidimensional chromatography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holland, L., & Jorgenson, J. W. (1995) · Analytical Chemistry · doi:10.1021/ac00114a026 · Cited by 128
Comprehensive two‐dimensional gas chromatography applied to the analysis of complex mixtures
Venkatramani, C. J., & Phillips, J. B. (1993) · Journal of Microcolumn Separations · doi:10.1002/mcs.1220050604 · Cited by 109
Near-infrared diffuse reflectance analysis of Athabasca oil sand
Shaw, R. C., & Kratochvil, B. G. (1990) · Analytical Chemistry · doi:10.1021/ac00201a016 · Cited by 63
Cited by
Pirok, B. W. J., Stoll, D. R., & Schoenmakers, P. J. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04841 · Cited by 358
Two-Dimensional Liquid Chromatography: A State of the Art Tutorial
Stoll, D. R., & Carr, P. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03506 · Cited by 347
Principles and applications of comprehensive two-dimensional gas chromatography
Marriott, P., & Shellie, R. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00814-2 · Cited by 282
Baghdady, Y. Z., & Schug, K. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01665 · Cited by 36
Metadata
- Authors
- Murphy, R. E., Schure, M. R., & Foley, J. P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-03-13
- Volume
- 70
- Issue
- 8
- Pages
- 1585-1594
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988098839
- Cited by
- 436
- References
- 3
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography. https://app.cochat.ai/papers/10.1021/ac971184b
- The paper
- Murphy, R. E., Schure, M. R., & Foley, J. P. (1998). Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac971184b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.