CoChat

Online Comprehensive High pH Reversed Phase × Low pH Reversed Phase Approach for Two-Dimensional Separations of Intact Proteins in Top-Down Proteomics

Baghdady, Yehia Z., Schug, Kevin A. · 2019 · Analytical Chemistry

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

A proof-of-concept study is presented on the use of comprehensive two-dimensional liquid chromatography mass spectrometry (LC × LC-MS) for the separation of intact protein mixtures using a different mobile phase pH in each dimension. This system utilizes mass spectrometry (MS) friendly pH modifiers for the online coupling of high pH reversed phase liquid chromatography (HPH-RPLC) in the first dimension ( 1 D) followed by low pH reversed phase liquid chromatography (LPH-RPLC) in the second dimension ( 2 D). Owing to the ionic nature of proteins, the use of a different mobile phase pH was successful to provide altered selectivity between the two dimensions, even for closely related protein variants, such as bovine cytochrome c and equine cytochrome c, which differ by only three amino acids. Subminute gradient separation of proteins in the second dimension was successful to minimize analysis time, while maintaining high peak capacity. Unlike peptides, the elution order of studied proteins did not follow their isoelectric points, where acidic proteins would be expected to be more retained at low pH (and basic proteins at high pH). The steep elution isotherms (on–off retention mechanism) of proteins and the very steep gradients utilized in the second-dimension column succeeded in overcoming pH and organic solvent content mismatch. The utility of the system was demonstrated with a mixture of protein standards and an Escherichia coli protein mixture.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b01665

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 46 references

Research works printed but not linked: 1

  1. Dong M., 1989, BioChromatography, 4, 19

Cited by

See all 36

Metadata

Authors
Baghdady, Y. Z., & Schug, K. A.
Affiliations
The University of Texas at Arlington (US)
Corresponding author
Schug, Kevin A.
Venue
Analytical Chemistry
Published
2019-08-01
Volume
91
Issue
17
Pages
11085-11091
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2966565804
Cited by
36
References
46
Citations by year
2026: 5 · 2025: 1 · 2024: 3 · 2023: 8 · 2022: 2 · 2021: 8 · 2020: 7 · 2019: 1
FWCI
1.79
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Restek Corporation
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
top-down proteomics, intact protein separation, two-dimensional liquid chromatography, mobile phase pH, isoelectric point, Escherichia coli proteins
MeSH terms
Proof of Concept Study, Animals, Carbonic Anhydrases, Caseins, Cattle, Escherichia coli, Horses, Hydrogen-Ion Concentration, Isoelectric Point, Lactalbumin, Lactoglobulins, Myoglobin, Mass Spectrometry, Escherichia coli Proteins, Proteomics, Cytochromes c, Complex Mixtures, Chromatography, Reverse-Phase

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Online Comprehensive High pH Reversed Phase × Low pH Reversed Phase Approach for Two-Dimensional Separations of Intact Proteins in Top-Down Proteomics. https://app.cochat.ai/papers/10.1021/acs.analchem.9b01665
The paper
Baghdady, Y. Z., & Schug, K. A. (2019). Online Comprehensive High pH Reversed Phase × Low pH Reversed Phase Approach for Two-Dimensional Separations of Intact Proteins in Top-Down Proteomics. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b01665

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.