The DOI matches its Crossref record.
Method To Compare Collision-Induced Dissociation Spectra of Peptides: Potential for Library Searching and Subtractive Analysis
Abstract
We report the development of a method to compare collision-induced dissociation (CID) spectra of peptides. This method employs a cross-correlation analysis of a CID spectrum to a reference spectrum and normalizes the cross-correlation score to the autocorrelation of the CID spectra. The query spectrum is compared by using both mass information and fragmentation patterns. Fragmentation patterns are compared to each other using a correlation function. To evaluate the specificity of the approach, a set of 2180 tandem mass spectra obtained from both triple-quadrupole tandem mass spectrometers (TSQ) and quadrupole ion trap mass spectrometers (LCQ) was created. Comparisons are performed between tandem mass spectra obtained on the same instrument type as well as between different instrument types. Accurate and reliable comparisons are demonstrated in both types of analyses. The scores obtained in the cross-comparison of TSQ and LCQ tandem mass spectra of the same peptide are found to be slightly lower than comparisons performed with spectra obtained on the same instrument type. The method appears insensitive to variations in day-to-day performance of the instrument, minor variations in fragment ion abundance, and instrumental differences inherent in the same instrument model. The use of this method of comparison is demonstrated for library searching and subtractive analysis of tandem mass spectra obtained during LC/MS/MS experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An Automated Multidimensional Protein Identification Technology for Shotgun Proteomics
Wolters, D. A., Washburn, M. P., & Yates, J. R. (2001) · Analytical Chemistry · doi:10.1021/ac010617e · Cited by 1,819
Self-citationAnalysis and validation of proteomic data generated by tandem mass spectrometry
Nesvizhskii, A. I., Vitek, O., & Aebersold, R. (2007) · Nature Methods · doi:10.1038/nmeth1088 · Cited by 629
Lam, H., Deutsch, E. W., Eddes, J. S., Eng, J. K., King, N., Stein, S. E., & Aebersold, R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600625 · Cited by 517
Self-citationNesvizhskii, A. I. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.08.009 · Cited by 536
Washburn, M. P., Ulaszek, R., Deciu, C., Schieltz, D. M., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac015704l · Cited by 390
Self-citation
Metadata
- Authors
- Yates, J. R., Morgan, S. F., Gatlin, C. L., Griffin, P. R., & Eng, J. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-07-30
- Volume
- 70
- Issue
- 17
- Pages
- 3557-3565
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2053827324
- Cited by
- 189
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method To Compare Collision-Induced Dissociation Spectra of Peptides: Potential for Library Searching and Subtractive Analysis. https://app.cochat.ai/papers/10.1021/ac980122y
- The paper
- Yates, J. R., Morgan, S. F., Gatlin, C. L., Griffin, P. R., & Eng, J. K. (1998). Method To Compare Collision-Induced Dissociation Spectra of Peptides: Potential for Library Searching and Subtractive Analysis. Analytical Chemistry. https://doi.org/10.1021/ac980122y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.