Capillary Electrophoresis Sodium Dodecyl Sulfate Nongel Sieving Analysis of a Therapeutic Recombinant Monoclonal Antibody: A Biotechnology Perspective
The DOI matches its Crossref record.
Abstract
With the increasing interest in the therapeutic use of recombinant monoclonal antibodies (rMAbs), a generic analytical approach for the analysis of size-based rMAb variants is desired. Such a method using capillary electrophoresis (CE) with laser-induced fluorescence detection is described. The assay was developed as a replacement for silver-stained SDS-PAGE and was validated according to the guidelines of the International Committee on Harmonization for use in routine lot release testing of a rMAb pharmaceutical. In this assay, the rMAb solution is first derivatized with a neutral fluorophore, e.g., 5-carboxytetramethylrhodamine succinimidyl ester. The labeled sample is then incubated with SDS, and the SDS-protein complexes are then separated by CE using a hydrophilic polymer as a sieving matrix. The precolumn labeling conditions described in this study allowed the detection of rMAb at a low-nanomolar concentration (9 ng/mL), with no apparent loss in resolution or changes to the distribution of rMAb analyte species, when compared to an unlabeled sample. In addition, the traditional practice of heating proteins at elevated temperatures in the presence of SDS to facilitate SDS-protein binding resulted in the generation of significant levels of rMAb fragmentation, and alternative conditions to minimize this artifact are discussed. Illustrations of the uses of this assay in monitoring consistency of bulk manufacture of a protein pharmaceutical, and in providing a size-based separation of product-related variants, as well as nonproduct impurities are shown. In brief, the assay described in this paper demonstrated comparable resolution and sensitivity to silver-stained SDS-PAGE but offered the advantages of enhanced precision and robustness, speed, ease of use, and on-line detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Identification of multiple sources of charge heterogeneity in a recombinant antibody
Harris, R. J., Kabakoff, B., Macchi, F. D., Shen, F. J., Kwong, M., Andya, J. D., Shire, S. J., Bjork, N., Totpal, K., & Chen, A. B. (2001) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)00548-x · Cited by 500
Heterogeneity of Monoclonal Antibodies
Liu, H., Gaza-Bulseco, G., Faldu, D., Chumsae, C., & Sun, J. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21180 · Cited by 481
Analytical methods for physicochemical characterization of antibody drug conjugates
Wakankar, A., Chen, Y., Gokarn, Y., & Jacobson, F. S. (2011) · mAbs · doi:10.4161/mabs.3.2.14960 · Cited by 382
Fragmentation of monoclonal antibodies
Vlasak, J., & Ionescu, R. (2011) · mAbs · doi:10.4161/mabs.3.3.15608 · Cited by 331
Huhn, C., Selman, M. H. J., Ruhaak, L. R., Deelder, A. M., & Wuhrer, M. (2009) · PROTEOMICS · doi:10.1002/pmic.200800715 · Cited by 301
Metadata
- Authors
- Hunt, G., & Nashabeh, W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-05-22
- Volume
- 71
- Issue
- 13
- Pages
- 2390-2397
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1989893455
- Cited by
- 154
- References
- 0
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary Electrophoresis Sodium Dodecyl Sulfate Nongel Sieving Analysis of a Therapeutic Recombinant Monoclonal Antibody: A Biotechnology Perspective. https://app.cochat.ai/papers/10.1021/ac981209m
- The paper
- Hunt, G., & Nashabeh, W. (1999). Capillary Electrophoresis Sodium Dodecyl Sulfate Nongel Sieving Analysis of a Therapeutic Recombinant Monoclonal Antibody: A Biotechnology Perspective. Analytical Chemistry. https://doi.org/10.1021/ac981209m
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.