The DOI matches its Crossref record.
Integration of Microfabricated Devices to Capillary Electrophoresis−Electrospray Mass Spectrometry Using a Low Dead Volume Connection: Application to Rapid Analyses of Proteolytic Digests
Abstract
This report describes the development of a compact and versatile, micromachined chip device enabling the efficient coupling of capillary electrophoresis to electrospray mass spectrometry (CE-ESMS). On-chip separation provides a convenient means of achieving rapid sample cleanup and resolution of multicomponent samples (typically 2-5 min) prior to mass spectral analysis. A low dead volume connection facilitating the coupling of microfabricated devices to CE-ESMS was evaluated using two different interfaces. The first configuration used disposable nanoelectrospray emitters directly coupled to the chip device via this low dead volume junction, thereby providing rapid separation of complex protein digests. The performance of this interface was compared with that of more traditional configurations using a sheath flow CE-ESMS arrangement where a fused-silica capillary of varying length enabled further temporal resolution of the multicomponent samples. The sensitivity and analytical characteristics of these interfaces were investigated in both negative and positive ion modes using standard peptide mixtures. The separation performance for synthetic peptides using a chip coated with amine reagent ranged from 26,000 to 58,000 theoretical plates for a sheath flow CE-ESMS interface comprising a 15-cm CE column. Replicate injections of a dilution series of peptide standards provided detection limits of 45-400 nM without the use of on-line preconcentration devices. The reproducibility of migration time ranged from 0.9 to 1.5% RSD whereas RSDs of 5-10% were observed on peak areas. The application of these devices for the analysis of protein digests was further evaluated using on-line tandem mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Airborne chemistry: acoustic levitation in chemical analysis
Santesson, S., & Nilsson, S. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2403-2 · Cited by 262
Metadata
- Authors
- Li, J., Thibault, P., Bings, N. H., Skinner, C. D., Wang, C., Colyer, C., & Harrison, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-06-15
- Volume
- 71
- Issue
- 15
- Pages
- 3036-3045
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2077877779
- Cited by
- 186
- References
- 0
- FWCI
- 15.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integration of Microfabricated Devices to Capillary Electrophoresis−Electrospray Mass Spectrometry Using a Low Dead Volume Connection: Application to Rapid Analyses of Proteolytic Digests. https://app.cochat.ai/papers/10.1021/ac981420y
- The paper
- Li, J., Thibault, P., Bings, N. H., Skinner, C. D., Wang, C., Colyer, C., & Harrison, J. (1999). Integration of Microfabricated Devices to Capillary Electrophoresis−Electrospray Mass Spectrometry Using a Low Dead Volume Connection: Application to Rapid Analyses of Proteolytic Digests. Analytical Chemistry. https://doi.org/10.1021/ac981420y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.