CoChat

Liquid−Liquid−Liquid Microextraction for Sample Preparation of Biological Fluids Prior to Capillary Electrophoresis

Pedersen-Bjergaard, Stig, Rasmussen, Knut Einar · 1999 · Analytical Chemistry

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Methamphetamine as a model compound was extracted from 2.5-mL aqueous samples adjusted to pH 13 (donor solution) through a thin phase of 1-octanol inside the pores of a polypropylene hollow fiber and finally into a 25-microL acidic acceptor solution inside the hollow fiber. Following this liquid-liquid-liquid microextraction (LLLME), the acceptor solutions were analyzed by capillary zone electrophoresis (CE). Extractions were performed in simple disposable devices each consisting of a conventional 4-mL sample vial, two needles for introduction and collection of the acceptor solution, and a 8-cm piece of a porous polypropylene hollow fiber. From 5 to 20 different samples were extracted in parallel for 45 min, providing a high sample capacity. Methamphetamine was preconcentrated by a factor of 75 from aqueous standard solutions, human urine, and human plasma utilizing 10(-1) M HCl as the acceptor phase and 10(-1) M NaOH in the donor solution. In addition to preconcentration, LLLME also served as a technique for sample cleanup since large molecules, acidic compounds, and neutral components were not extracted into the acceptor phase. Utilizing diphenhydramine hydrochloride as internal standard, repetitive extractions varied less than 5.2% RSD (n = 6), while the calibration curve for methamphetamine was linear within the range 20 ng/microL to 10 micrograms/mL (r = 0.9983). The detection limit of methamphetamine utilizing LLLME/CE was 5 ng/mL (S/N = 3) in both human urine and plasma.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac990055n

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. Altria K. D., 1997, LC-GC, 15, 448
  2. Moring S. E., 1989, LC-GC, 8, 34
  3. Tomlinson A. J., 1995, J. Capillary Electrophor., 2, 97
  4. Pálmarsdóttir S., 1995, J. Capillary Electrophor., 2, 185

Cited by

See all 1,245

Metadata

Authors
Pedersen-Bjergaard, S., & Rasmussen, K. E.
Affiliations
  • School of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
  • University of Oslo (NO)
Venue
Analytical Chemistry
Published
1999-06-08
Volume
71
Issue
14
Pages
2650-2656
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2048705571
Cited by
1,245
References
16
Citations by year
2026: 16 · 2025: 23 · 2024: 34 · 2023: 31 · 2022: 36 · 2021: 33 · 2020: 51 · 2019: 59 · 2018: 53 · 2017: 53 · 2016: 59 · 2015: 84 · 2014: 76 · 2013: 86 · 2012: 107
FWCI
12.10
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
Keywords
hollow fiber membranes, methamphetamine, capillary zone electrophoresis, preconcentration, sample cleanup, human urine, human plasma, biological fluids, 1-octanol
MeSH terms
Diphenhydramine, Humans, Methamphetamine, Reference Standards, Spectrophotometry, Ultraviolet, Reproducibility of Results, Electrophoresis, Capillary

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.