The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Immunoassay Readout Method Using Extrinsic Raman Labels Adsorbed on Immunogold Colloids
Abstract
An immunoassay readout method based on surface-enhanced Raman scattering (SERS) is described. The method exploits the SERS-derived signal from reporter molecules that are coimmobilized with biospecific species on gold colloids. This concept is demonstrated in a dualanalyte sandwich assay, in which two different antibodies covalently bound to a solid substrate specifically capture two different antigens from an aqueous sample. The captured antigens in turn bind selectively to their corresponding detection antibodies. The detection antibodies are conjugated with gold colloids that are labeled with different Raman reporter molecules, which serve as extrinsic labels for each type of antibody. The presence of a specific antigen is established by the characteristic SERS spectrum of the reporter molecule. A near-infrared diode laser was used to excite efficiently the SERS signal while minimizing fluorescence interference. We show that, by using different labels with little spectral overlap, two different antigenic species can be detected simultaneously. The potential of this concept to function as a readout strategy for multiple analytes is briefly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vo-Dinh, T. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00069-7 · Cited by 498
Cited by
SERS as a bioassay platform: fundamentals, design, and applications
Porter, M. D., Lipert, R. J., Siperko, L. M., Wang, G., & Narayanan, R. (2008) · Chemical Society Reviews · doi:10.1039/b708461g · Cited by 580
Self-citationPenn, S. G., He, L., & Natan, M. J. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.013 · Cited by 512
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Surface-enhanced Raman spectroscopy: a half-century historical perspective
Yi, J., You, E.-M., Hu, R., Wu, D.-Y., Liu, G.-K., Yang, Z.-L., Zhang, H., Gu, Y., Wang, Y.-H., Wang, X., et al. (2025) · Chemical Society Reviews · doi:10.1039/d4cs00883a · Cited by 382
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Stimulated Raman Scattering: From Bulk to Nano
Prince, R. C., Frontiera, R. R., & Potma, E. O. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00545 · Cited by 350
Spectral Analysis of Multiplex Raman Probe Signatures
Lutz, B. R., Dentinger, C. E., Nguyen, L. N., Sun, L., Zhang, J., Allen, A. N., Chan, S., & Knudsen, B. S. (2008) · ACS Nano · doi:10.1021/nn800243g · Cited by 135
Metadata
- Authors
- Ni, J., Lipert, R. J., Dawson, G. B., & Porter, M. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-09-23
- Volume
- 71
- Issue
- 21
- Pages
- 4903-4908
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2032347877
- Cited by
- 443
- References
- 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.