Absorption of Hydrophobic Compounds into the Poly(dimethylsiloxane) Coating of Solid-Phase Microextraction Fibers: High Partition Coefficients and Fluorescence Microscopy Images
Open accessAbstract
The use of solid-phase microextraction with poly(dimethylsiloxane) (PDMS)-coated glass fibers for the extraction and analysis of hydrophobic organic analytes is increasing. The literature on this topic is characterized by large discrepancies in partition coefficients and an uncertainty of whether highly hydrophobic analytes are retained by absorption into the fiber coating or by adsorption to the fiber surface. We applied a new method, which minimizes the impact of experimental artifacts, to determine PDMS water partition coefficients of 17 hydrophobic analytes including chlorinated benzenes, PCBs, PAHs, and p,p'-DDE. These partition coefficients are several orders of magnitude higher than some reported values. Two observations strongly suggest that the retention of hydrophobic organic substances is governed by partitioning into the PDMS coating. (1) The partition coefficients are proportional with octanol/water partition coefficients. (2) The fluorescence of fluoranthene was observed to be homogeneously distributed within the polymer coating when studied by means of fluorescence microscopy. Implications of these findings for the application of solid-phase microextraction with respect to potential detection limits, with respect to biomimetic extraction, and with respect to measurements in multicompartment systems are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid-phase microextraction of polychlorinated biphenyls
Yang, Y., Miller, D. J., & Hawthorne, S. B. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01115-1 · Cited by 116
Cited by
Rodrigues, J. P., Duarte, A. C., Santos-Echeandía, J., & Rocha-Santos, T. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.038 · Cited by 491
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Digital Microfluidics with In-Line Sample Purification for Proteomics Analyses with MALDI-MS
Wheeler, A. R., Moon, H., Bird, C. A., Ogorzalek Loo, R. R., Kim, C.-J. “. J. ”., Loo, J. A., & Garrell, R. L. (2005) · Analytical Chemistry · doi:10.1021/ac048754+ · Cited by 255
Metadata
- Authors
- Mayer, P., Vaes, W. H. J., & Hermens, J. L. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-12-28
- Volume
- 72
- Issue
- 3
- Pages
- 459-464
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2026294795
- Cited by
- 183
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.