The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
Abstract
A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
A systematic nomenclature for carbohydrate fragmentations in FAB-MS/MS spectra of glycoconjugates
Domon, B., & Costello, C. E. (1988) · Glycoconjugate Journal · doi:10.1007/bf01049915 · Cited by 2,729
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Ion formation in MALDI mass spectrometry
Zenobi, R., & Knochenmuss, R. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:5<337::aid-mas2>3.0.co;2-s · Cited by 819
Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Vestal, M. L., Juhasz, P., & Martin, S. A. (1995) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290091115 · Cited by 497
Enhancement of uphill transport by a double carrier membrane system
Sugawara, M., Omoto, M., Yoshida, H., & Umezawa, Y. (1988) · Analytical Chemistry · doi:10.1021/ac00171a029 · Cited by 320
Time‐of‐flight mass spectrometry
Cotter, R. J. (2005) · Encyclopedia of Genetics, Genomics, Proteomics and Bioinformatics · doi:10.1002/047001153x.g301302 · Cited by 211
Colby, S. M., King, T. B., Reilly, J. P., & Lubman, D. M. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290081102 · Cited by 166
Dzięgielewska, K. M., Brown, W. M., Casey, S. J., et al. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)39571-7 · Cited by 137
Medzihradszky, K. F., Maltby, D. A., Hall, S. C., Settineri, C. A., & Burlingame, A. L. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85050-x · Cited by 71
Self-citation
Cited by
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
The Desorption Process in MALDI
Dreisewerd, K. (2003) · Chemical Reviews · doi:10.1021/cr010375i · Cited by 709
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Kompauer, M., Heiles, S., & Spengler, B. (2017) · Nature Methods · doi:10.1038/nmeth.4071 · Cited by 600
Metadata
- Authors
- Laiko, V. V., Baldwin, M. A., & Burlingame, A. L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-01-20
- Volume
- 72
- Issue
- 4
- Pages
- 652-657
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2028995205
- Cited by
- 411
- References
- 10
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.