Site-Specific Mass Tagging with Stable Isotopes in Proteins for Accurate and Efficient Protein Identification
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Proteolytic peptide mass mapping as measured by mass spectrometry provides a major approach for the identification of proteins. A protein is usually identified by the best match between the measured and calculated m/z values of the proteolytic peptides. A unique identification is, however, heavily dependent upon the mass accuracy and sequence coverage of the fragment ions generated by peptide ionization. Without ultrahigh instrumental accuracy, it is possible to increase the specificity of the assignments of particular proteolytic peptides by the incorporation of selected amino acid residue(s) enriched with stable isotope(s) into the protein sequence. Here we report this novel method of generating residue-specific mass-tagged proteolytic peptides for accurate and efficient protein identification. Selected amino acids are labeled with 13C/15N/2H and incorporated into proteins in a sequence-specific manner during cell culturing. Each of these labeled amino acids carries a defined mass change encoded in its monoisotopic distribution pattern. Through their characteristic patterns, the peptides with mass tags can then be readily distinguished from other peptides in mass spectra. This method of identifying unique proteins can also be extended to protein complexes and will significantly increase data search specificity, efficiency, and accuracy for protein identifications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Cited by
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Dynamics of Protein Turnover, a Missing Dimension in Proteomics
Pratt, J. M., Petty, J., Riba-Garcia, I., Robertson, D. H. L., Gaskell, S. J., Oliver, S. G., & Beynon, R. J. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200046-mcp200 · Cited by 396
18 O Labeling: a tool for proteomics
Stewart, I. I., Thomson, T., & Figeys, D. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.525 · Cited by 327
Lei, Y., Wen, H., Yu, Y., Taxman, D. J., Zhang, L., Widman, D. G., Swanson, K. V., Wen, K.-W., Damania, B., Moore, C. B., et al. (2012) · Immunity · doi:10.1016/j.immuni.2012.03.025 · Cited by 295
Self-citationQuantitative Mass Spectrometry-Based Proteomics: An Overview
Rozanova, S., Barkovits, K., Nikolov, M., Schmidt, C., Urlaub, H., & Marcus, K. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-1024-4_8 · Cited by 275
Metadata
- Authors
- Chen, X., Smith, L. M., & Bradbury, E. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-02-16
- Volume
- 72
- Issue
- 6
- Pages
- 1134-1143
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2038151309
- Cited by
- 117
- References
- 1
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.