Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Probing Specific Sequences on Single DNA Molecules with Bioconjugated Fluorescent Nanoparticles

Taylor, Jason R., Fang, Michelle M., Nie, Shuming·2000·Analytical Chemistry

Abstract

Nanometer-sized fluorescent particles (latex nanobeads) have been covalently linked to DNA binding proteins to probe specific sequences on stretched single DNA molecules. In comparison with single organic fluorophores, these nanoparticle probes are brighter, are more stable against photobleaching, and do not suffer from intermittent on/off light emission (blinking). Specifically, we demonstrate that the site-specific restriction enzyme EcoRI can be conjugated to 20-nm fluorescent nanoparticles and that the resulting nanoconjugates display DNA binding and cleavage activities of the native enzyme. In the absence of cofactor magnesium ions, the EcoRI conjugates bind to specific sequences on double-stranded DNA but do not initiate enzymatic cutting. For single DNA molecules that are stretched and immobilized on a solid surface, nanoparticles bound at specific sites can be directly visualized by multicolor fluorescence microscopy. Direct observation of site-specific probes on single DNA molecules opens new possibilities in optical gene mapping and in the fundamental study of DNA-protein interactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac9913311

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 249

Metadata

Authors
Taylor, J. R., Fang, M. M., & Nie, S.
Venue
Analytical Chemistry
Published
2000-03-29
Volume
72
Issue
9
Pages
1979-1986
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2074682130
Cited by
249
References
4
FWCI
3.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.