Aggregation-Induced Emission Luminogens for Activity-Based Sensing
The DOI matches its Crossref record; 65 of the 66 references it cites were found in a registry or an index.
Abstract
Fluorescent sensing has emerged as a powerful tool for detecting various analytes and visualizing numerous biological processes by virtue of its superb sensitivity, rapidness, excellent temporal resolution, easy operation, and low cost. Of particular interest is activity-based sensing (ABS), a burgeoning sensing approach that is actualized on the basis of dynamic molecular reactivity rather than conventional lock-and-key molecular recognition. ABS has been recognized to possess some distinct advantages, such as high specificity, extraordinary sensitivity, and accurate signal outputs. A majority of ABS sensors are constructed by modifying conventional fluorogens, which are strongly emissive when molecularly dissolved in solvents but experience emission quenching upon aggregate formation or concentration increase. The aggregation-caused quenching (ACQ) phenomenon leads to a limited amount of labeling of the analyte with the sensor and low photobleaching resistance, which could impede practical applications of the ABS protocol. As an anti-ACQ phenomenon, aggregation-induced emission (AIE) provides a straightforward solution to the ACQ problem. Thanks to their intrinsic advantages, including high photobleaching threshold, high signal-to-noise ratio, fluorescence turn-on nature, and large Stokes shift, AIE-active luminogens (AIEgens) represent a class of extraordinary fluorogen alternatives for the ABS protocol. The use of AIEgen-involved ABS can integrate the advantages of AIEgens and ABS, and additionally, the AIE process offers some unique properties to the ABS approach. For instance, in some cases of water-soluble AIEgen-involved ABS, chemical reaction not only leads to a chang in the emission color of the AIEgens but also causes solubility variations, which could result in specific "light-up" signaling. In this Account, the basic concepts and mechanistic insights of the ABS approach involving the AIE principle are briefly summarized, and then we highlight the new breakthroughs, seminal studies, and trends in the area that have been most recently reported by our group. This emerging sensing protocol has been successfully utilized for detecting an array of targets including ions, small molecules, biomacromolecules, and microenvironments, all of which closely relate to human health, medical, and public concerns. These detections are smoothly achieved on the basis of various reactions (e.g., hydrolysis, boronate cleavage, dephosphorylation, addition, cyclization, and rearrangement reactions) through different sensing principles. In these studies, the AIEgen-involved ABS strategy generally shows good biocompatibility, high selectivity, excellent reliability and high signal contrast, strongly indicating its great potential for high-tech innovations in the sensing field, among which bioprobing is of particular interest. With this Account, we hope to spark new ideas and inspire new endeavors in this emerging research area, further promoting state-of-the-art developments in the field of sensing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Aggregation-induced emission of 1-methyl-1,2,3,4,5-pentaphenylsilole
Luo, J., Xie, Z., Lam, J. W. Y., Cheng, L., Tang, B. Z., Chen, H., Qiu, C., Kwok, H. S., Zhan, X., Liu, Y., et al. (2001) · Chemical Communications · doi:10.1039/b105159h · Cited by 8,358
Self-citationAggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationPhotophysics of aromatic molecules
Sharnoff, M. (1971) · Journal of Luminescence · doi:10.1016/0022-2313(71)90011-1 · Cited by 4,482
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Self-citationThe Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Reaction-based small-molecule fluorescent probes for chemoselective bioimaging
Chan, J., Dodani, S. C., & Chang, C. J. (2012) · Nature Chemistry · doi:10.1038/nchem.1500 · Cited by 1,883
Bioprobes Based on AIE Fluorogens
Ding, D., Li, K., Liu, B., & Tang, B. Z. (2013) · Accounts of Chemical Research · doi:10.1021/ar3003464 · Cited by 1,817
Self-citationSmall molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Biosensing by luminogens with aggregation-induced emission characteristics
Kwok, R. T. K., Leung, C. W. T., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00325j · Cited by 1,296
Self-citation
Cited by
Design of superior phototheranostic agents guided by Jablonski diagrams
Feng, G., Zhang, G.-Q., & Ding, D. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00671h · Cited by 783
Aggregation‐Induced Emission: Recent Advances in Materials and Biomedical Applications
Cai, X., & Liu, B. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202000845 · Cited by 796
Supramolecular materials based on AIE luminogens (AIEgens): construction and applications
Li, J., Wang, J., Li, H., Song, N., Wang, D., & Tang, B. Z. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00495e · Cited by 741
Self-citationAggregation‐enhanced theranostics: AIE sparkles in biomedical field
Kang, M., Zhang, Z., Song, N., Li, M., Sun, P., Chen, X., Wang, D., & Tang, B. Z. (2020) · Aggregate · doi:10.1002/agt2.7 · Cited by 485
Self-citationLi, Y., Cai, Z., Liu, S., Zhang, H., Wong, S. T. H., Lam, J. W. Y., Kwok, R. T. K., Qian, J., & Tang, B. Z. (2020) · Nature Communications · doi:10.1038/s41467-020-15095-1 · Cited by 464
Self-citation
Metadata
- Authors
- Wang, D., & Tang, B. Z.
- Affiliations
- Shenzhen University (CN)
- Hong Kong University of Science and Technology (HK)
- Corresponding author
- Wang, Dong
- Tang, Ben Zhong
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-08-22
- Volume
- 52
- Issue
- 9
- Pages
- 2559-2570
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2969652379
- Cited by
- 510
- References
- 66
- Citations by year
- 2026: 35 · 2025: 60 · 2024: 90 · 2023: 79 · 2022: 86 · 2021: 71 · 2020: 81 · 2019: 8
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Accounts of Chemical Research (publishedVersion)
- PubMed (publishedVersion)
- Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
- Funders
- Ministry of Science and Technology of the People's Republic of China (2013CB834702, 2013CB834701)
- University Grants Committee (AoE/P-03/08)
- National Natural Science Foundation of China (21801169)
- Natural science foundation of Shenzhen University (2019004)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- aggregation-induced emission, AIEgens, aggregation-caused quenching, fluorescent sensors, dephosphorylation, cyclization, rearrangement reactions, ion detection, biomolecule detection, microenvironment sensing, biocompatibility, photobleaching resistance
- MeSH terms
- Fluorescent Dyes, Humans, Ions, Macromolecular Substances, Small Molecule Libraries
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Aggregation-Induced Emission Luminogens for Activity-Based Sensing. https://app.cochat.ai/papers/10.1021/acs.accounts.9b00305
- The paper
- Wang, D., & Tang, B. Z. (2019). Aggregation-Induced Emission Luminogens for Activity-Based Sensing. Accounts of Chemical Research. https://doi.org/10.1021/acs.accounts.9b00305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.