Native Mass Spectrometry Imaging of Proteins and Protein Complexes by Nano-DESI
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Previously, we have demonstrated native mass spectrometry imaging (native MSI) in which the spatial distribution of proteins maintained in their native-like, folded conformations was determined using liquid extraction surface analysis (LESA). While providing an excellent testbed for proof of principle, the spatial resolution of LESA is currently limited for imaging primarily by the physical size of the sampling pipette tip. Here, we report the adoption of nanospray-desorption electrospray ionization (nano-DESI) for native MSI, delivering substantial improvements in resolution versus native LESA MSI. In addition, native nano-DESI may be used for location-targeted top-down proteomics analysis directly from tissue. Proteins, including a homodimeric complex not previously detected by native MSI, were identified through a combination of collisional activation, high-resolution MS and proton transfer charge reduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
Kompauer, M., Heiles, S., & Spengler, B. (2017) · Nature Methods · doi:10.1038/nmeth.4071 · Cited by 600
Dynamics of ions of intact proteins in the Orbitrap mass analyzer
Makarov, A., & Denisov, E. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.03.024 · Cited by 194
Ion/Ion Proton Transfer Reactions for Protein Mixture Analysis
Stephenson, J. L., & McLuckey, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac9605657 · Cited by 145
The Role of the Detergent Micelle in Preserving the Structure of Membrane Proteins in the Gas Phase
Reading, E., Liko, I., Allison, T. M., Benesch, J. L. P., Laganowsky, A., & Robinson, C. V. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411622 · Cited by 137
Cited by
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202200721 · Cited by 54
Chapman, E. A., Roberts, D. S., Tiambeng, T. N., Andrews, J., Wang, M.-D., Reasoner, E. A., Melby, J. A., Li, B. H., Kim, D., Alpert, A. J., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-43321-z · Cited by 28
Spatial top-down proteomics for the functional characterization of human kidney
(2025) · doi:10.1186/s12014-025-09531-x · Cited by 15
Proteoform‐Selective Imaging of Tissues Using Mass Spectrometry**
Yang, M., Hu, H., Su, P., Thomas, P. M., Camarillo, J. M., Greer, J. B., Early, B. P., Fellers, R. T., Kelleher, N. L., & Laskin, J. (2022) · Angewandte Chemie · doi:10.1002/ange.202200721 · Cited by 6
Metadata
- Authors
- Hale, O. J., & Cooper, H. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-03-04
- Volume
- 93
- Issue
- 10
- Pages
- 4619-4627
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W3134020177
- Cited by
- 131
- References
- 6
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.