Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Nelly: A User-Friendly and Open-Source Implementation of Tree-Based Complex Refractive Index Analysis for Terahertz Spectroscopy

Abstract

Terahertz (THz) spectroscopy is a powerful tool for unambiguously extracting complex-valued material properties (e.g., refractive index, conductivity, etc.) from a wide range of samples, with applications ranging from materials science to biology. However, extracting complex refractive indices from THz time-domain spectroscopy data can prove challenging, especially for multilayer samples. These challenges arise from the large number of transmission-reflection paths the THz pulse can take through the sample layers, leading to unwieldy strings of Fresnel coefficients. This issue has often been addressed using various approximations. However, these approximations are only applicable to specific classes of samples and can give erroneous results when misapplied. An alternative to this approach is to programmatically model all possible paths through the sample. The many paths through the sample layers can be modeled as a tree that branches at every point where the paths diverge, i.e., whenever the pulse can either be transmitted or reflected. This tree can then be used to generate expressions relating the unknown refractive index to the observed time domain data. Here, we provide a freely available open-source package implementing this method as both a MATLAB library and a corresponding graphical user interface, which can also be run without a MATLAB license ( https://github.com/YaleTHz/nelly ). We have tested this method for a range of samples and compared the results to commonly used approximations to demonstrate its accuracy and wide applicability. Our method consistently gives better agreement than common approximations.

Overview

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c02132

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Cited by

See all 41

Metadata

Authors
Tayvah, U., Spies, J. A., Neu, J., & Schmuttenmaer, C. A.
Affiliations
Yale University (US)
Corresponding author
  • Tayvah, Uriel
  • Neu, Jens
Venue
Analytical Chemistry
Published
2021-08-06
Volume
93
Issue
32
Pages
11243-11250
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W3191845429
Cited by
41
References
26
Citations by year
2026: 6 · 2025: 11 · 2024: 7 · 2023: 11 · 2022: 6
FWCI
1.76
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Science Foundation (1954453, DGE-1752134)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
terahertz spectroscopy, complex refractive index, Fresnel coefficients, multilayer samples, open source software, MATLAB toolbox, graphical user interface, Nelly
MeSH terms
Refractometry, Terahertz Spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nelly: A User-Friendly and Open-Source Implementation of Tree-Based Complex Refractive Index Analysis for Terahertz Spectroscopy. https://app.cochat.ai/papers/10.1021/acs.analchem.1c02132
The paper
Tayvah, U., Spies, J. A., Neu, J., & Schmuttenmaer, C. A. (2021). Nelly: A User-Friendly and Open-Source Implementation of Tree-Based Complex Refractive Index Analysis for Terahertz Spectroscopy. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.1c02132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.