CoChat

A Broad-Specificity O -Glycoprotease That Enables Improved Analysis of Glycoproteins and Glycopeptides Containing Intact Complex O -Glycans

Open access
Vainauskas, Saulius, Guntz, Hélène, McLeod, Elizabeth, McClung, Colleen, Ruse, Cristian, Shi, Xiaofeng, Taron, Christopher H. · 2022 · Analytical Chemistry
Cited by 67

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Abstract Analysis of mucin type O-glycans linked to serine/threonine of glycoproteins is technically challenging, in part, due to a lack of effective enzymatic tools that enable their analysis. Recently, several O-glycan-specific endoproteases that can cleave the protein adjacent to the appended glycan have been described. Despite significant progress in understanding the biochemistry of these enzymes, known O-glycoproteases have specificity constrains, such as inefficient cleavage of glycoproteins bearing sialylated O-glycans, high selectivity for certain type of glycoproteins or protein sequence bias, that limit their analytical application. In this study, we examined the capabilities of an immunomodulating metalloprotease (IMPa) from Pseudomonas aeruginosa . The peptide substrate sequence selectivity and its impact on IMPa activity was interrogated using an array of synthetic peptides and their glycoforms. We show that IMPa has no specific P1 residue preference and can tolerate most amino acids at the P1 position, except aspartic acid. The enzyme does not cleave between two adjacent O-glycosites, indicating that O-glycosylated serine/threonine is not allowed at position P1. Glycopeptides with as few as two amino acids on either side of an O-glycosite were specifically cleaved by IMPa. Finally, IMPa efficiently cleaved peptides and proteins carrying sialylated and asialylated O-glycans of varying complexity. We present the use of IMPa in a one-step O-glycoproteomics workflow for glycoprofiling of individual purified glycoproteins granulocyte colony-stimulating factor (G-CSF) and receptor-type tyrosine-protein phosphatase C (CD45) without the need for glycopeptide enrichment. In these examples, IMPa enabled identification of O-glycosites and the range of complex O-glycan structures at each site.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.1c04055

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Vainauskas, S., Guntz, H., McLeod, E., McClung, C., Ruse, C., Shi, X., & Taron, C. H.
Venue
Analytical Chemistry
Published
2021-12-28
Volume
94
Issue
2
Pages
1060-1069
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W4220822888
Cited by
67
References
6
FWCI
2.15
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.