ACEstat: A DIY Guide to Unlocking the Potential of Integrated Circuit Potentiostats for Open-Source Electrochemical Analysis
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Miniaturization of analytical instrumentation is paramount to enabling convenient in-field sensing. The recent thrust in potentiostat miniaturization for electrochemical sensing and general use has led to the development of commercial application specific integrated circuits (ASICs) that pack all the power of a benchtop instrument into one 5 mm × 5 mm chip. While the capabilities of these integrated circuits far exceed those of open-source potentiostats in the literature, the activation barrier for their implementation requires extensive electrical and software engineering expertise to overcome. In order to more rapidly bring the utility of ASIC potentiostats to researchers, we present a low size, weight, power, and cost (Low SWaP-C) Army Corps of Engineers potentiostat (ACEstat) based on the widely available ADuCM355 offered by Analog Devices. This potentiostat is a streamlined and fully programmable device that leverages industry-leading integrated hardware to perform electrochemical measurements such as cyclic voltammetry, pulse voltammetry, and electrochemical impedance spectroscopy. The ACEstat enables control over a wide range of test parameters and displays results through an intuitive, open-source graphical user interface available on mobile devices and computers. In this report, we present an approachable, do-it-yourself guide to unlocking the capabilities of this integrated circuit potentiostat by outlining the fabrication and programming details necessary to facilitate electroanalysis. Furthermore, we demonstrate the practicality of this device by detecting 2,4,6-trinitrotoluene (TNT) in water at sub-mg/L detection limits, highlighting its potential for in-field use.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Bakker, E., & Telting-Diaz, M. (2002) · Analytical Chemistry · doi:10.1021/ac0202278 · Cited by 662
Open-Source Potentiostat for Wireless Electrochemical Detection with Smartphones
Ainla, A., Mousavi, M. P. S., Tsaloglou, M.-N., Redston, J., Bell, J. G., Fernández-Abedul, M. T., & Whitesides, G. M. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00850 · Cited by 360
Privett, B. J., Shin, J. H., & Schoenfisch, M. H. (2010) · Analytical Chemistry · doi:10.1021/ac101075n · Cited by 334
DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration
Dryden, M. D. M., & Wheeler, A. R. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140349 · Cited by 221
Wang, J., Hocevar, S. B., & Ogorevc, B. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2003.11.010 · Cited by 220
Ngamchuea, K., Eloul, S., Tschulik, K., & Compton, R. G. (2014) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-014-2664-z · Cited by 200
Electrochemical Sensing of Perfluorooctanesulfonate (PFOS) Using Ambient Oxygen in River Water
Clark, R. B., & Dick, J. E. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01894 · Cited by 164
Disposable electrochemical sensors: A mini review
Thiyagarajan, N., Chang, J.-L., Senthilkumar, K., & Zen, J.-M. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2013.11.016 · Cited by 160
Research works printed but not linked: 4
- 10.1021/acsapm.1c00575 · DOI
- Hwang H., 2007, Electrochemical Analysis
- Glasscott, M. W. Nanodroplet-Mediated Electrodeposition: Fundamental Principles and Applications to Nanomaterial Synthesis. Ph.D. Thesis, The University of North Carolina at Chapel Hill, Chapel Hill, NC, 2021.
- 10.1021/acsomega.0c04776 · DOI
Cited by
Bilbao, E., Garate, O. F., Campos, T. R., Roberti, M., Mass, M., Lozano, A., Longinotti, G., Monsalve, L. N., & Ybarra, G. (2023) · Chemosensors · doi:10.3390/chemosensors11040244 · Cited by 50
“Finally, with a higher level of integration and design specificity, there are potentiostats based on application specific integrated circuits (ASICs) [118,119], such as ADuCM355 from Analog Devices [120], in which the AFE and all of the digital processing blocks were integrated into a single chip.”
Rodríguez, O., Pence, M. A., & Rodríguez‐López, J. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04862 · Cited by 30
Zhou, G., & Liu, H. (2026) · Biosensors · doi:10.3390/bios16020112 · Cited by 51
Achieving broad availability of SARS-CoV-2 detections via smartphone-based analysis
Li, D., Sun, C., Mei, X., & Yang, L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116878 · Cited by 23
Novel interfaces for internet of wearable electrochemical sensors
Shahzad, S., Iftikhar, F. J., Shah, A., Rehman, H. A., & Iwuoha, E. I. (2024) · RSC Advances · doi:10.1039/d4ra07165d · Cited by 28
An affordable platform for automated synthesis and electrochemical characterization
Pablo‐García, S., García, A., Akkoc, G. D., Sim, M., Cao, Y., Somers, M., Hattrick, C., Yoshikawa, N., Dworschak, D., Hao, H., et al. (2024) · Device · doi:10.1016/j.device.2024.100567 · Cited by 29
PolArStat: An Arduino based potentiostat for low-power electrochemical applications
(2023) · doi:10.1016/j.electacta.2023.143119 · Cited by 19
“The ACEstat [21] is based on the ADuCM355-microchip, specifically designed for chemical sensing purposes.”
HELPStat: A Handheld, EIS-Enabled, Low-Cost, and Portable Potentiostat
Bautista, K. A., Madsen, E., Riegle, S., & Linnes, J. C. (2024) · ACS electrochemistry. · doi:10.1021/acselectrochem.4c00052 · Cited by 13
Demirhan, A., Ekşin, E., Kılıç, Y., & Erdem, A. (2022) · Micromachines · doi:10.3390/mi13101610 · Cited by 10
Cruz‐Pacheco, A. F., Avendaño, S. E., & Orozco, J. (2025) · Electrochimica Acta · doi:10.1016/j.electacta.2025.147759 · Cited by 9
A portable device for real-time continuous drug monitoring in freely moving small animals
Tsyban, Y., Shetty, S. S., Li, Y., Filho, J. I. D. O., Merzaban, J. S., & Salama, K. N. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117704 · Cited by 6
Fuente-Ballesteros, A., Samanidou, V., & Zuin, V. G. (2026) · RSC Sustainability · doi:10.1039/d6su00052e · Cited by 4
Sawazaki, M. R. B., Bachour, B., Mulato, M., & Filho, J. I. D. O. (2025) · Advanced Intelligent Discovery · doi:10.1002/aidi.202500049 · Cited by 2
Chuang, K.-W., Li, P.-K., Huang, Y., & Liao, Y. (2025) · Langmuir · doi:10.1021/acs.langmuir.5c04977 · Cited by 3
Sensor ToolKit (STK): Compact Multiplexing Potentiostat for Point-of-Care Applications
Acosta, A. A. A., Maya, A. M., Saporito, S., Kleinstraß, M., Mitrovics, J., Blondeau, P., & Andrade, F. J. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.5c07176 · Cited by 1
Watkins, Z., McHenry, A., & Heikenfeld, J. C. (2023) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2023_238 · Cited by 2
Rabea, A. F., Hanafi, E., Kumal, S. R., Khairuddin, A. S. M., & Leo, B. F. (2025) · IEEE Access · doi:10.1109/access.2025.3614293 · Cited by 4
“ACEstat [61] provides excellent reproducibility, but is costly and USB dependent.”
Miniaturized electrochemical devices: from lab to field
Queijo, A. R., Styszko, K., & Rego, R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33399-6.00012-2 · Cited by 1
An Affordable Platform for Automated Synthesis and Electrochemical CharacterizationPreprint
Pablo‐García, S., Garcı́a, A., Akkoc, G. D., Sim, M., Cao, Y., Somers, M., Hattrick, C., Yoshikawa, N., Dworschak, D., Hao, H., et al. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4815518 · Cited by 1
(2025) · doi:10.1109/ropec68163.2025.11353954
“Notable examples include the ABE-stat [4], which incorporates wireless communication with an Android app, and the ACEstat [5], which uses an ARM Cortex M3 microcontroller to improve resolution.”
Lobert, S., Sheikh, Z. R., Yazdi, N., Goderis, D., & Mason, A. J. (2026) · Sensors · doi:10.3390/s26175334
Metadata
- Authors
- Brown, E. W., Glasscott, M. W., Conley, K., Barr, J., Ray, J. D., Moores, L. C., & Netchaev, A.
- Affiliations
- U.S. Army Engineer Research and Development Center (US)
- Corresponding author
- Netchaev, Anton
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-03-08
- Volume
- 94
- Issue
- 12
- Pages
- 4906-4912
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W4220876512
- Cited by
- 34
- References
- 33
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 10 · 2023: 6 · 2022: 2
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- potentiostat, application-specific integrated circuits, open-source hardware, cyclic voltammetry, pulse voltammetry, electrochemical impedance spectroscopy, explosives detection, graphical user interface
- MeSH terms
- Electricity, Electrodes, Electrochemical Techniques, Dielectric Spectroscopy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.