DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration
Open accessAbstract
Most electroanalytical techniques require the precise control of the potentials in an electrochemical cell using a potentiostat. Commercial potentiostats function as "black boxes," giving limited information about their circuitry and behaviour which can make development of new measurement techniques and integration with other instruments challenging. Recently, a number of lab-built potentiostats have emerged with various design goals including low manufacturing cost and field-portability, but notably lacking is an accessible potentiostat designed for general lab use, focusing on measurement quality combined with ease of use and versatility. To fill this gap, we introduce DStat (http://microfluidics.utoronto.ca/dstat), an open-source, general-purpose potentiostat for use alone or integrated with other instruments. DStat offers picoampere current measurement capabilities, a compact USB-powered design, and user-friendly cross-platform software. DStat is easy and inexpensive to build, may be modified freely, and achieves good performance at low current levels not accessible to other lab-built instruments. In head-to-head tests, DStat's voltammetric measurements are much more sensitive than those of "CheapStat" (a popular open-source potentiostat described previously), and are comparable to those of a compact commercial "black box" potentiostat. Likewise, in head-to-head tests, DStat's potentiometric precision is similar to that of a commercial pH meter. Most importantly, the versatility of DStat was demonstrated through integration with the open-source DropBot digital microfluidics platform. In sum, we propose that DStat is a valuable contribution to the "open source" movement in analytical science, which is allowing users to adapt their tools to their experiments rather than alter their experiments to be compatible with their tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 31
- A Bewick, 1963, The design and performance of potentiostats, Biochem Biophys Res Commun, 8, 89
- Bembnowicz P, Yang GZ, Anastasova S, Spehar-Deleze AM, Vadgama P. Wearable electronic sensor for potentiometric and amperometric measurements. In: 2013 IEEE International Conference on Body Sensor Networks (BSN). IEEE; 2013. p. 1–5. · doi:10.1109/bsn.2013.6575531
- S Kwakye, 2007, An embedded system for portable electrochemical detection, Sens Actuators, B, 123, 336, 10.1016/j.snb.2006.08.032 · DOI
- CY Huang, 2007, A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting, Biosens Bioelectron, 22, 1694, 10.1016/j.bios.2006.07.036 · doi:10.1016/j.bios.2006.07.036
- RD Beach, 2005, Towards a Miniature Implantable In Vivo Telemetry Monitoring System Dynamically Configurable as a Potentiostat or Galvanostat for Two- and Three-Electrode Biosensors, IEEE Trans Instrum Meas, 54, 61, 10.1109/TIM.2004.839757 · doi:10.1109/tim.2004.839757
- A Gore, 2006, A Multichannel Femtoampere-Sensitivity Potentiostat Array for Biosensing Applications, IEEE Trans Circuits Syst I, 53, 2357, 10.1109/TCSI.2006.884432 · doi:10.1109/tcsi.2006.884432
- AA Rowe, 2011, CheapStat: An Open-Source, “Do-It-Yourself” Potentiostat for Analytical and Educational Applications, PLoS ONE, 6, e23783, 10.1371/journal.pone.0023783 · DOI · Paper page
- ES Friedman, 2012, A cost-effective and field-ready potentiostat that poises subsurface electrodes to monitor bacterial respiration, Biosens Bioelectron, 32, 309, 10.1016/j.bios.2011.12.013 · DOI
- AV Gopinath, 2005, An inexpensive field-portable programmable potentiostat, Chem Educ
- AFD Cruz, 2014, A low-cost miniaturized potentiostat for point-of-care diagnosis, Biosens Bioelectron, 62, 249, 10.1016/j.bios.2014.06.053 · DOI · Paper page
- MD Steinberg, 2004, A micropower amperometric potentiostat, Sens Actuators, B, 97, 284, 10.1016/j.snb.2003.09.002 · doi:10.1016/j.snb.2003.09.002
- M Stanacevic, 2007, VLSI Potentiostat Array With Oversampling Gain Modulation for Wide-Range Neurotransmitter Sensing, IEEE Trans Biomed Circuits Syst, 1, 63, 10.1109/TBCAS.2007.893176 · DOI
- VK Cumyn, 2003, Design and testing of a low-cost multichannel pseudopotentiostat for quantitative combinatorial electrochemical measurements on large electrode arrays, Electrochem Solid-State Lett, 6, E15, 10.1149/1.1570031 · DOI
- Li H, Luo X, Liu C, Jiang L, Cui D, Cai X, et al. Multi-channel electrochemical detection system based on LabVIEW. In: Proceedings of the 2004 International Conference on Information Acquisition, ICIA 2004; 2004. p. 224–227.
- R Gostowski, 1996, Teaching Analytical Instrument Design with LabVIEW, J Chem Educ, 73, 1103, 10.1021/ed073p1103 · doi:10.1021/ed073p1103
- Z Stević, 2008, A New PC and LabVIEW Package Based System for Electrochemical Investigations, Sensors 2008, Vol 8, Pages 1819–1831, 8, 1819
- PL Urban, 2015, Universal electronics for miniature and automated chemical assays, Analyst, 140, 963, 10.1039/C4AN02013H · DOI
- L Soleymani, 2009, Nanostructuring of Patterned Microelectrodes To Enhance the Sensitivity of Electrochemical Nucleic Acids Detection, Angew Chem Int Ed, 48, 8457, 10.1002/anie.200902439 · DOI
- TC McIlvaine, 1921, A BUFFER SOLUTION FOR COLORIMETRIC COMPARISON, J Biol Chem, 183, 10.1016/S0021-9258(18)86000-8 · DOI · Paper page
- L Soleymani, 2009, Programming the detection limits of biosensors through controlled nanostructuring, Nature Nanotech, 4, 844, 10.1038/nnano.2009.276 · DOI · Paper page
- L Soleymani, 2011, Hierarchical Nanotextured Microelectrodes Overcome the Molecular Transport Barrier To Achieve Rapid, Direct Bacterial Detection, ACS Nano, 5, 3360, 10.1021/nn200586s · DOI
- B Lam, 2012, Polymerase Chain Reaction-Free, Sample-to-Answer Bacterial Detection in 30 Minutes with Integrated Cell Lysis, Anal Chem, 84, 21, 10.1021/ac202599b · DOI
- GA Zelada-Guillén, 2010, Real-Time Potentiometric Detection of Bacteria in Complex Samples, Anal Chem, 82, 9254, 10.1021/ac101739b · DOI · Paper page
- F Winquist, 2002, Electronic Tongues and Combinations of Artificial Senses, Sens Update, 11, 279, 10.1002/seup.200211107 · DOI
- R Fobel, 2013, DropBot: An open-source digital microfluidic control system with precise control of electrostatic driving force and instantaneous drop velocity measurement, Appl Phys Lett, 102, 193513, 10.1063/1.4807118 · DOI · Paper page
- MH Shamsi, 2014, A digital microfluidic electrochemical immunoassay, Lab Chip, 14, 547, 10.1039/C3LC51063H · DOI
- Y Yu, 2013, Microfabrication of a digital microfluidic platform integrated with an on-chip electrochemical cell, J Micromech Microeng, 23, 095025, 10.1088/0960-1317/23/9/095025 · doi:10.1088/0960-1317/23/9/095025
- MDM Dryden, 2013, Integrated Digital Microfluidic Platform for Voltammetric Analysis, Anal Chem, 85, 8809, 10.1021/ac402003v · DOI
- C Karuwan, 2011, Electrochemical detection on electrowetting-on-dielectric digital microfluidic chip, Talanta, 84, 1384, 10.1016/j.talanta.2011.03.073 · doi:10.1016/j.talanta.2011.03.073
- DG Rackus, 2015, A digital microfluidic device with integrated nanostructured microelectrodes for electrochemical immunoassays, Lab Chip, 15, 3776, 10.1039/C5LC00660K · DOI
- SS Zhao, 2015, Miniature multi-channel SPR instrument for methotrexate monitoring in clinical samples, Biosens Bioelectron, 64, 664, 10.1016/j.bios.2014.09.082 · DOI
Cited by
Open-Source Potentiostat for Wireless Electrochemical Detection with Smartphones
Ainla, A., Mousavi, M. P. S., Tsaloglou, M.-N., Redston, J., Bell, J. G., Fernández-Abedul, M. T., & Whitesides, G. M. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00850 · Cited by 360
Thiamine deficiency disorders: Diagnosis, prevalence, and a roadmap for global control programs
Whitfield, K. C., Bourassa, M. W., Adamolekun, B., Bergeron, G., Bettendorff, L., Brown, K. H., Cox, L., Fattal‐Valevski, A., Fischer, P. R., Frank, E. L., et al. (2018) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13919 · Cited by 336
Electrochemical paper-based devices: sensing approaches and progress toward practical applications
Noviana, E., McCord, C. P., Clark, K. M., Jang, I., & Henry, C. S. (2020) · Lab on a Chip · doi:10.1039/c9lc00903e · Cited by 321
Brown, E. W., Glasscott, M. W., Conley, K., Barr, J., Ray, J. D., Moores, L. C., & Netchaev, A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04226 · Cited by 34
Metadata
- Authors
- Dryden, M. D. M., & Wheeler, A. R.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-10-28
- Volume
- 10
- Issue
- 10
- Pages
- e0140349
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1868251798
- Cited by
- 221
- References
- 0
- FWCI
- 6.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration. https://app.cochat.ai/papers/10.1371/journal.pone.0140349
- The paper
- Dryden, M. D. M., & Wheeler, A. R. (2015). DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration. PLOS ONE. https://doi.org/10.1371/journal.pone.0140349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.