The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Near-Infrared and Naked-Eye Fluorescence Probe for Direct and Highly Selective Detection of Cysteine and Its Application in Living Cells
Abstract
The near-infrared (NIR) fluorescence sensor for rapid, selective, and sensitive detection of cystenine (Cys) is of great importance in both biological and environmental sciences. Herein, we report a specific probe with turn-on fluorescence property, visible color change with naked-eye, and large wavelength shift on UV spectra for highly selective detection of Cys over homocysteine (Hcy) and glutathione (GSH) in both HEPES buffer (10 mM, pH 7.4) and diluted human serum. The probe based on the conjugate addition-cyclization reaction has a low limit of detection to Cys (0.16 μM as NIR fluorescence sensor and 0.13 μM as UV sensor). Kinetic study indicated that the probe has a very rapid response to Cys, owing to the much higher pseudo-first-order reaction constant with Cys (299 M(-1) s(-1)) than with Hcy (1.29 M(-1) s(-1)) or GSH (0.53 M(-1) s(-1)). Upon addition of Cys to a solution of the probe, the color changed from purple to cyan, with the maximum wavelength shifting from 582 to 674 nm in the UV spectrum and a fluorescence emission at 697 nm appearing. It has been successfully applied for determination of Cys in diluted serum and bioimaging of Cys in living cells with low cell toxicity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma Homocysteine as a Risk Factor for Dementia and Alzheimer's Disease
Seshadri, S., Beiser, A., Selhub, J., Jacques, P. F., Rosenberg, I. H., D'Agostino, R. B., Wilson, P. W. F., & Wolf, P. A. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa011613 · Cited by 3,237
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Cited by
Niu, H., Liu, J., O’Connor, H. M., Gunnlaugsson, T., James, T. D., & Zhang, H. (2023) · Chemical Society Reviews · doi:10.1039/d1cs01097b · Cited by 449
Self-citation
Metadata
- Authors
- Zhang, J., Wang, J., Liu, J., Ning, L., Zhu, X., Yu, B., Liu, X., Yao, X., & Zhang, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-04-22
- Volume
- 87
- Issue
- 9
- Pages
- 4856-4863
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2333559885
- Cited by
- 204
- References
- 2
- FWCI
- 13.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared and Naked-Eye Fluorescence Probe for Direct and Highly Selective Detection of Cysteine and Its Application in Living Cells. https://app.cochat.ai/papers/10.1021/acs.analchem.5b00377
- The paper
- Zhang, J., Wang, J., Liu, J., Ning, L., Zhu, X., Yu, B., Liu, X., Yao, X., & Zhang, H. (2015). Near-Infrared and Naked-Eye Fluorescence Probe for Direct and Highly Selective Detection of Cysteine and Its Application in Living Cells. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b00377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.