Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion

Lei, Yan-Mei, Huang, Wei-Xing, Zhao, Min, Chai, Ya-Qin, Yuan, Ruo, Zhuo, Ying · 2015 · Analytical Chemistry

Abstract

In this paper, a novel electrochemiluminescence resonance energy transfer (ECL-RET) system from O2/S2O8(2-) to a kind of amino-terminated perylene derivative (PTC-NH2) was demonstrated for the first time, which was then applied to construct a ratiometric aptasensor for lead ion (Pb(2+)) detection. First, gold-nanoparticles-functionalized fullerene nanocomposites (AuNPs@nano-C60) were coated on a glassy carbon electrode (GCE), and then thiol-modified assistant probes (APs) were attached on AuNPs@nano-C60/GCE. Then the resultant electrode was hybridized with capture probes (the aptamer of the Pb(2+), abbreviated as CPs) to generate DNA duplexes, which could induce PTC-NH2 to be intercalated into the dsDNA grooves by the electrostatic adsorption. Herein, ECL dual peaks at -0.7 V (vs Ag/AgCl) and -2.0 V (vs Ag/AgCl) were obtained when the prepared aptasensor was detected in air-saturated S2O8(2-) solution, which could be attributed to the emission of excited dimmers (π-excimers) ((1)(NH2-PTC)2*) and (1)(O2)2*, respectively. In the presence of Pb(2+), the dsDNA was unwound, and Pb(2+) G-quadruplex structure was generated because of the highly specific affinity between Pb(2+) and CPs, which made the PTC-NH2 release from the electrode surface. As a result, the ECL signal at -0.7 V was decreased, and the ECL signal around -2.0 V was increased. By measuring the ratio of ECL intensities at two excitation potentials, the developed aptasensor exhibited the linear response range from 1.0 × 10(-12) M to 1.0 × 10(-7) M with a detection limit of 3.5 × 10(-13) M (S/N = 3) for Pb(2+), which could offer an alternative analytical method with excellent properties of high selectivity, accuracy, and sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b01445

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 161

Metadata

Authors
Lei, Y.-M., Huang, W.-X., Zhao, M., Chai, Y.-Q., Yuan, R., & Zhuo, Y.
Venue
Analytical Chemistry
Published
2015-07-21
Volume
87
Issue
15
Pages
7787-7794
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2304195178
Cited by
161
References
1
FWCI
8.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion. https://app.cochat.ai/papers/10.1021/acs.analchem.5b01445
The paper
Lei, Y.-M., Huang, W.-X., Zhao, M., Chai, Y.-Q., Yuan, R., & Zhuo, Y. (2015). Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b01445

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.