The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion
Abstract
In this paper, a novel electrochemiluminescence resonance energy transfer (ECL-RET) system from O2/S2O8(2-) to a kind of amino-terminated perylene derivative (PTC-NH2) was demonstrated for the first time, which was then applied to construct a ratiometric aptasensor for lead ion (Pb(2+)) detection. First, gold-nanoparticles-functionalized fullerene nanocomposites (AuNPs@nano-C60) were coated on a glassy carbon electrode (GCE), and then thiol-modified assistant probes (APs) were attached on AuNPs@nano-C60/GCE. Then the resultant electrode was hybridized with capture probes (the aptamer of the Pb(2+), abbreviated as CPs) to generate DNA duplexes, which could induce PTC-NH2 to be intercalated into the dsDNA grooves by the electrostatic adsorption. Herein, ECL dual peaks at -0.7 V (vs Ag/AgCl) and -2.0 V (vs Ag/AgCl) were obtained when the prepared aptasensor was detected in air-saturated S2O8(2-) solution, which could be attributed to the emission of excited dimmers (π-excimers) ((1)(NH2-PTC)2*) and (1)(O2)2*, respectively. In the presence of Pb(2+), the dsDNA was unwound, and Pb(2+) G-quadruplex structure was generated because of the highly specific affinity between Pb(2+) and CPs, which made the PTC-NH2 release from the electrode surface. As a result, the ECL signal at -0.7 V was decreased, and the ECL signal around -2.0 V was increased. By measuring the ratio of ECL intensities at two excitation potentials, the developed aptasensor exhibited the linear response range from 1.0 × 10(-12) M to 1.0 × 10(-7) M with a detection limit of 3.5 × 10(-13) M (S/N = 3) for Pb(2+), which could offer an alternative analytical method with excellent properties of high selectivity, accuracy, and sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequential extraction procedure for the speciation of particulate trace metals
Tessier, A., Campbell, P. G. C., & Bisson, M. (1979) · Analytical Chemistry · doi:10.1021/ac50043a017 · Cited by 12,052
Cited by
Nanoparticles: Properties, applications and toxicities
Khan, I., Saeed, K., & Khan, I. (2019) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2017.05.011 · Cited by 6,244
Ijaz, I., Gilani, E., Nazir, A., & Bukhari, A. (2020) · Green Chemistry Letters and Reviews · doi:10.1080/17518253.2020.1802517 · Cited by 992
Nucleic Acid Biosensors: Recent Advances and Perspectives
Du, Y., & Dong, S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04190 · Cited by 429
Nanomaterials-based sensitive electrochemiluminescence biosensing
Chen, Y., Zhou, S., Li, L., & Zhu, J.-J. (2017) · Nano Today · doi:10.1016/j.nantod.2016.12.013 · Cited by 337
Qin, L., Zeng, G., Lai, C., Huang, D., Xu, P., Zhang, C., Cheng, M., Liu, X., Liu, S., Li, B., et al. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.01.006 · Cited by 332
Metadata
- Authors
- Lei, Y.-M., Huang, W.-X., Zhao, M., Chai, Y.-Q., Yuan, R., & Zhuo, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-07-21
- Volume
- 87
- Issue
- 15
- Pages
- 7787-7794
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2304195178
- Cited by
- 161
- References
- 1
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion. https://app.cochat.ai/papers/10.1021/acs.analchem.5b01445
- The paper
- Lei, Y.-M., Huang, W.-X., Zhao, M., Chai, Y.-Q., Yuan, R., & Zhuo, Y. (2015). Electrochemiluminescence Resonance Energy Transfer System: Mechanism and Application in Ratiometric Aptasensor for Lead Ion. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b01445
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.