The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Simple and Effective Way for Data Preprocessing Selection Based on Design of Experiments
Open accessAbstract
The selection of optimal preprocessing is among the main bottlenecks in chemometric data analysis. Preprocessing currently is a burden, since a multitude of different preprocessing methods is available for, e.g., baseline correction, smoothing, and alignment, but it is not clear beforehand which method(s) should be used for which data set. The process of preprocessing selection is often limited to trial-and-error and is therefore considered somewhat subjective. In this paper, we present a novel, simple, and effective approach for preprocessing selection. The defining feature of this approach is a design of experiments. On the basis of the design, model performance of a few well-chosen preprocessing methods, and combinations thereof (called strategies) is evaluated. Interpretation of the main effects and interactions subsequently enables the selection of an optimal preprocessing strategy. The presented approach is applied to eight different spectroscopic data sets, covering both calibration and classification challenges. We show that the approach is able to select a preprocessing strategy which improves model performance by at least 50% compared to the raw data; in most cases, it leads to a strategy very close to the true optimum. Our approach makes preprocessing selection fast, insightful, and objective.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
SIMPLS: An alternative approach to partial least squares regression
de Jong, S. (1993) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)85002-x · Cited by 1,905
Assessment of PLSDA Cross Validation
Westerhuis, J. A., Hoefsloot, H. C. J., Smit, S., Vis, D. J., Smilde, A. K., van Velzen, E. J. J., van Duijnhoven, J. P. M., & van Dorsten, F. A. (2008) · Metabolomics · doi:10.1007/s11306-007-0099-6 · Cited by 1,471
Martens, H., & Stark, E. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80188-f · Cited by 515
Cited by
Convolutional neural networks for vibrational spectroscopic data analysis
Acquarelli, J., van Laarhoven, T., Gerretzen, J., Tran, T. N., Buydens, L. M. C., & Marchiori, E. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.12.010 · Cited by 472
Self-citationDeepSpectra: An end-to-end deep learning approach for quantitative spectral analysis
Zhang, X., Lin, T., Xu, J., Luo, X., & Ying, Y. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.01.002 · Cited by 375
Wang, H.-P., Chen, P., Dai, J.-W., Liu, D., Li, J.-Y., Xu, Y.-P., & Chu, X.-L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116648 · Cited by 326
Deep learning for vibrational spectral analysis: Recent progress and a practical guide
Yang, J., Xu, J., Zhang, X., Wu, C., Lin, T., & Ying, Y. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.012 · Cited by 299
Metadata
- Authors
- Gerretzen, J., Szymańska, E., Jansen, J. J., Bart, J., van Manen, H.-J., van den Heuvel, E. R., & Buydens, L. M. C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-03
- Volume
- 87
- Issue
- 24
- Pages
- 12096-12103
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2436973322
- Cited by
- 191
- References
- 4
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple and Effective Way for Data Preprocessing Selection Based on Design of Experiments. https://app.cochat.ai/papers/10.1021/acs.analchem.5b02832
- The paper
- Gerretzen, J., Szymańska, E., Jansen, J. J., Bart, J., van Manen, H.-J., van den Heuvel, E. R., & Buydens, L. M. C. (2015). Simple and Effective Way for Data Preprocessing Selection Based on Design of Experiments. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b02832
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.