Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record.

Microfluidic Distance Readout Sweet Hydrogel Integrated Paper-Based Analytical Device (μDiSH-PAD) for Visual Quantitative Point-of-Care Testing

Wei, Xiaofeng, Tian, Tian, Jia, Shasha, Zhu, Zhi, Ma, Yanli, Sun, Jianjun, Lin, Zhenyu, Yang, Chaoyong James · 2016 · Analytical Chemistry

Abstract

A disposable, equipment-free, versatile point-of-care testing platform, microfluidic distance readout sweet hydrogel integrated paper-based analytical device (μDiSH-PAD), was developed for portable quantitative detection of different types of targets. The platform relies on a target-responsive aptamer cross-linked hydrogel for target recognition, cascade enzymatic reactions for signal amplification, and microfluidic paper-based analytic devices (μPADs) for visual distance-based quantitative readout. A "sweet" hydrogel with trapped glucoamylase (GA) was synthesized using an aptamer as a cross-linker. When target is present in the sample, the "sweet" hydrogel collapses and releases enzyme GA into the sample, generating glucose by amylolysis. A hydrophilic channel on the μPADs is modified with glucose oxidase (GOx) and colorless 3,3'-diaminobenzidine (DAB) as the substrate. When glucose travels along the channel by capillary action, it is converted to H2O2 by GOx. In addition, DAB is converted into brown insoluble poly-3,3'-diaminobenzidine [poly(DAB)] by horseradish peroxidase, producing a visible brown bar, whose length is positively correlated to the concentration of targets. The distance-based visual quantitative platform can detect cocaine in urine with high selectivity, sensitivity, and accuracy. Because the target-induced cascade reaction is triggered by aptamer/target recognition, this method is widely suitable for different kinds of targets. With the advantages of low cost, ease of operation, general applicability, and disposability with quantitative readout, the μDiSH-PAD holds great potential for portable detection of trace targets in environmental monitoring, security inspection, personalized healthcare, and clinical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.5b04294

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Wei, X., Tian, T., Jia, S., Zhu, Z., Ma, Y., Sun, J., Lin, Z., & Yang, C. J.
Venue
Analytical Chemistry
Published
2016-01-27
Volume
88
Issue
4
Pages
2345-2352
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2287718491
Cited by
210
References
0
FWCI
12.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfluidic Distance Readout Sweet Hydrogel Integrated Paper-Based Analytical Device (μDiSH-PAD) for Visual Quantitative Point-of-Care Testing. https://app.cochat.ai/papers/10.1021/acs.analchem.5b04294
The paper
Wei, X., Tian, T., Jia, S., Zhu, Z., Ma, Y., Sun, J., Lin, Z., & Yang, C. J. (2016). Microfluidic Distance Readout Sweet Hydrogel Integrated Paper-Based Analytical Device (μDiSH-PAD) for Visual Quantitative Point-of-Care Testing. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5b04294

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.