The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Reversible Fluorescent Probe for Selective Detection and Cell Imaging of Oxidative Stress Indicator Bisulfite
Abstract
In this paper, we report a benzothiazole-functionalized cyanine fluorescence probe and demonstrate that it is selectively reactive to bisulfite, an intermediate indicator for oxidative stress. The selective reaction can be monitored by distinct ratiometric fluorescence variation favorable for cell imaging and visualization. The original probe can be regenerated in high yield through the elimination of bisulfite from the product by peroxides such as hydrogen peroxide, accompanied by fluorescence turning on at 590 nm, showing a potential application for the detection of peroxides. We successfully applied this probe for fluorescence imaging of bisulfite in cancer cells (MCF-7) treated with bisulfite and hydrogen peroxide as well as a selective detection limit of 0.34 μM bisulfite in aqueous solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
H 2 O 2 , a Necessary Evil for Cell Signaling
Rhee, S. G. (2006) · Science · doi:10.1126/science.1130481 · Cited by 2,160
The PerR transcription factor senses H2O2 by metal-catalysed histidine oxidation
Lee, J.-W., & Helmann, J. D. (2006) · Nature · doi:10.1038/nature04537 · Cited by 547
Cited by
Dual-Site Fluorescent Probe for Visualizing the Metabolism of Cys in Living Cells
Yue, Y., Huo, F., Ning, P., Zhang, Y., Chao, J., Meng, X., & Yin, C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12845 · Cited by 499
Self-citationJiao, X., Li, Y., Niu, J., Xie, X., Wang, X., & Tang, B. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04234 · Cited by 484
Metadata
- Authors
- Zhang, Y., Guan, L., Yu, H., Yan, Y., Du, L., Liu, Y., Sun, M., Huang, D., & Wang, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-04-07
- Volume
- 88
- Issue
- 8
- Pages
- 4426-4431
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2331330662
- Cited by
- 198
- References
- 2
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reversible Fluorescent Probe for Selective Detection and Cell Imaging of Oxidative Stress Indicator Bisulfite. https://app.cochat.ai/papers/10.1021/acs.analchem.6b00061
- The paper
- Zhang, Y., Guan, L., Yu, H., Yan, Y., Du, L., Liu, Y., Sun, M., Huang, D., & Wang, S. (2016). Reversible Fluorescent Probe for Selective Detection and Cell Imaging of Oxidative Stress Indicator Bisulfite. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6b00061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.