Real-Time Specific Light-Up Sensing of Transferrin Receptor: Image-Guided Photodynamic Ablation of Cancer Cells through Controlled Cytomembrane Disintegration
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Transferrin receptor (TfR) represents a unique target for specific imaging of cancer cells and targeted delivery of therapeutic reagents. Detection and qualification of TfR is thus of great importance for cancer diagnosis and therapy. In this contribution, a light-up probe TPETH-2T7 was developed by conjugating a red-emissive photosensitizer with aggregation-induced emission (AIE) characteristics to a TfR-targeting peptide T7. The probe is almost nonemissive by itself, but it gives turn-on fluorescence in the presence of TfR with a detection limit of 0.45 μg/mL. Cellular experiments show that the probe specifically binds to TfR-overexpressed cancer cells. Real-time imaging results reveal that the probe stains the MDA-MB-231 cell membrane in 30 min, which is followed by probe internalization. Experiments on image-guided photodynamic cancer ablation show that the therapeutic performance is better when TPETH-2T7 is localized on the cell membrane as compared to that being internalized into cells. Confocal laser scanning microscopy (CLSM) study reveals that cytomembrane disintegration allows quick ablation of MDA-MB-231 cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The transferrin receptor and the targeted delivery of therapeutic agents against cancer
Daniels, T. R., Bernabeu, E., Rodríguez, J. A., Patel, S., Kozman, M., Chiappetta, D. A., Holler, E., Ljubimova, J. Y., Helguera, G., & Penichet, M. L. (2012) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2011.07.016 · Cited by 807
Specific light-up bioprobes based on AIEgen conjugates
Liang, J., Tang, B. Z., & Liu, B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00444b · Cited by 762
Self-citation
Cited by
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813
Photosensitizers with Aggregation‐Induced Emission: Materials and Biomedical Applications
Hu, F., Xu, S., & Liu, B. (2018) · Advanced Materials · doi:10.1002/adma.201801350 · Cited by 859
Self-citationAggregation‐Induced Emission: Recent Advances in Materials and Biomedical Applications
Cai, X., & Liu, B. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202000845 · Cited by 796
Self-citationAIE Luminogens for Bioimaging and Theranostics: From Organelles to Animals
Qian, J., & Tang, B. Z. (2017) · Chem · doi:10.1016/j.chempr.2017.05.010 · Cited by 577
Aggregation‐enhanced theranostics: AIE sparkles in biomedical field
Kang, M., Zhang, Z., Song, N., Li, M., Sun, P., Chen, X., Wang, D., & Tang, B. Z. (2020) · Aggregate · doi:10.1002/agt2.7 · Cited by 485
Metadata
- Authors
- Zhang, R., Feng, G., Zhang, C.-J., Cai, X., Cheng, X., & Liu, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-04-13
- Volume
- 88
- Issue
- 9
- Pages
- 4841-4848
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2313450977
- Cited by
- 58
- References
- 2
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.