The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Three-Dimensional Ni2P Nanoarray: An Efficient Catalyst Electrode for Sensitive and Selective Nonenzymatic Glucose Sensing with High Specificity
Abstract
It is highly attractive to construct a natural enzyme-free electrode for sensitive and selective detection of glucose. In this Letter, we report that a Ni2P nanoarray on conductive carbon cloth (Ni2P NA/CC) behaves as an efficient three-dimensional catalyst electrode for glucose electrooxidation under alkaline conditions. Electrochemical measurements demonstrate that the Ni2P NA/CC, when used as a nonenzymatic glucose sensor, offers superior analytical performances with a short response time of 5 s, a wide detection range of 1 μM to 3 mM, a low detection limit of 0.18 μM (S/N = 3), a response sensitivity of 7792 μA mM(-1) cm(-2), and satisfactory selectivity, specificity, and reproducibility. Moreover, it can also be used for glucose detection in human blood serum, promising its application toward determination of glucose in real samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructured Nickel Phosphide as an Electrocatalyst for the Hydrogen Evolution Reaction
Popczun, E. J., McKone, J. R., Read, C. G., Biacchi, A. J., Wiltrout, A. M., Lewis, N. S., & Schaak, R. E. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403440e · Cited by 2,911
Pan, Y., Liu, Y., Zhao, J., Yang, K., Liang, J., Liu, D., Hu, W., Liu, D., Liu, Y., & Liu, C. (2015) · Journal of Materials Chemistry A · doi:10.1039/c4ta04867a · Cited by 652
Self-citationWang, X., Kolen'ko, Y. V., Bao, X., Kovnir, K., & Liu, L. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201502577 · Cited by 554
Cited by
Tang, C., Zhang, R., Lu, W., Wang, Z., Liu, D., Hao, S., Du, G., Asiri, A. M., & Sun, X. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201608899 · Cited by 809
Self-citationRecent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Liu, T., Liu, D., Qu, F., Wang, D., Zhang, L., Ge, R., Hao, S., Ma, Y., Du, G., Asiri, A. M., et al. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201700020 · Cited by 601
Self-citationElectrochemical non-enzymatic glucose sensors: recent progress and perspectives
Wei, M., Qiao, Y., Zhao, H., Liang, J., Li, T., Luo, Y., Lu, S., Shi, X., Lu, W., & Sun, X. (2020) · Chemical Communications · doi:10.1039/d0cc05650b · Cited by 467
Self-citationXie, L., Zhang, R., Cui, L., Liu, D., Hao, S., Ma, Y., Du, G., Asiri, A. M., & Sun, X. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201610776 · Cited by 388
Self-citation
Metadata
- Authors
- Chen, T., Liu, D., Lu, W., Wang, K., Du, G., Asiri, A. M., & Sun, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-08-05
- Volume
- 88
- Issue
- 16
- Pages
- 7885-7889
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2490807277
- Cited by
- 230
- References
- 3
- FWCI
- 16.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.