Using an Optical Probe as the Microdrop Holder in Headspace Single Drop Microextraction: Determination of Sulfite in Food Samples
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel headspace single-drop microextraction method (HS-SDME) for determination of sulfite in the form of sulfur dioxide was developed. An optical probe was used as the droplet holder in the HS-SDME procedure, and the analytical signal (absorbance) was monitored online during the extraction process. The method is based on the conversion of sulfite to volatile sulfur dioxide by acidification of the analyzed solution. The liberated SO 2 was absorbed by 25 μL of an aqueous mixed reagent solution placed on the optical probe tip and containing Fe(III), 1,10-phenantroline, and an acetic buffer solution of pH 5.6. During the extraction process, Fe(III) reduces to Fe(II) and the Fe(II) formed then reacts with 1,10-phenantroline to form a colored complex. Absorbance was measured at 510 nm. The calibration plot was linear in the range 0.032–0.320 mg L –1 of sulfite (as SO 2 ), with a correlation coefficient of 0.9989. The limit of detection (LOD), calculated as three times the standard deviation of the blank test ( n = 10), was found to be 8 μg L –1 . The method was applied for analysis of real food samples, such as wine, jam, and juice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Liquid-phase microextraction – The different principles and configurations
Yamini, Y., Rezazadeh, M., & Seidi, S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.06.010 · Cited by 309
Tang, S., Qi, T., Ansah, P. D., Nalouzebi Fouemina, J. C., Shen, W., Basheer, C., & Lee, H. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.09.016 · Cited by 195
Liquid-phase microextraction: update May 2016 to December 2018
Campillo, N., Gavazov, K., Viñas, P., Hagarova, I., & Andruch, V. (2020) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2019.1604537 · Cited by 45
Self-citationDetermination of Sulfur Dioxide in Food by Liquid Chromatography with Pre-Column Derivatization
Mu, L., Li, G., Kang, Q., Xu, Y., Fu, Y., & Ye, L. (2022) · Food Control · doi:10.1016/j.foodcont.2021.108500 · Cited by 30
Metadata
- Authors
- Zaruba, S., Vishnikin, A. B., Škrlíková, J., & Andruch, V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-10-06
- Volume
- 88
- Issue
- 20
- Pages
- 10296-10300
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2524299740
- Cited by
- 66
- References
- 1
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using an Optical Probe as the Microdrop Holder in Headspace Single Drop Microextraction: Determination of Sulfite in Food Samples. https://app.cochat.ai/papers/10.1021/acs.analchem.6b03129
- The paper
- Zaruba, S., Vishnikin, A. B., Škrlíková, J., & Andruch, V. (2016). Using an Optical Probe as the Microdrop Holder in Headspace Single Drop Microextraction: Determination of Sulfite in Food Samples. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.6b03129
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.