The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Ultratrace Naked-Eye Colorimetric Detection of Hg2+ in Wastewater and Serum Utilizing Mercury-Stimulated Peroxidase Mimetic Activity of Reduced Graphene Oxide-PEI-Pd Nanohybrids
Abstract
Herein, we developed a general strategy for rapid, highly selective, and ultratrace naked-eye colorimetric detection of Hg 2+ in aqueous solutions. Two dimensional rGO/PEI/Pd nanohybrids, where rGO, PEI, and Pd were referred to as reduced graphene oxide, polyethylenimine, and Pd nanoparticles, respectively, were synthesized and used as mimetic peroxidase for selective and ultrasensitive detection of Hg 2+ in water and human serum samples. In the presence of mercury ions, the peroxidase mimetic activity of rGO/PEI/Pd nanohybrids was found to be stimulated and enhanced significantly, which promoted the effective oxidation and color change of 3,3′,5,5′-tetramethylbenzidine (TMB) in solution to dark blue that was detected by the naked-eye and the absorption spectroscopic method. The proposed sensing strategy coupled with spectroscopic detection method showed an ultralow detection limit of 0.39 nM for Hg 2+ in ddH 2 O and ∼1 nM in wastewater as well as serum samples, respectively. On the basis of the colorimetric assay, a minimum concentration of ∼10 nM for Hg 2+ in wastewater and human serum can be detected with the naked-eye. The naked-eye-based colorimetric assay for sensitive and selective detection of mercury is expected to hold huge potentials in applications such as environmental monitoring, clinical diagnosis, and pharmaceutical analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Neurotoxicity and molecular effects of methylmercury
Castoldi, A. F., Coccini, T., Ceccatelli, S., & Manzo, L. (2001) · Brain Research Bulletin · doi:10.1016/s0361-9230(01)00458-0 · Cited by 348
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Flexible Graphene-Based Wearable Gas and Chemical Sensors
Singh, E., Meyyappan, M., & Nalwa, H. S. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07063 · Cited by 776
Carbon Nanozymes: Enzymatic Properties, Catalytic Mechanism, and Applications
Sun, H., Zhou, Y., Ren, J., & Qu, X. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712469 · Cited by 648
Applications of carbon dots in environmental pollution control: A review
Long, C., Jiang, Z., Shangguan, J., Qing, T., Zhang, P., & Feng, B. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.126848 · Cited by 434
Immunomodulation‐Enhanced Nanozyme‐Based Tumor Catalytic Therapy
Xu, B., Cui, Y., Wang, W., Li, S., Lyu, C., Wang, S., Bao, W., Wang, H., Qin, M., Liu, Z., et al. (2020) · Advanced Materials · doi:10.1002/adma.202003563 · Cited by 404
Metadata
- Authors
- Zhang, S., Zhang, D., Zhang, X., Shang, D., Xue, Z., Shan, D., & Lu, X.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-02-27
- Volume
- 89
- Issue
- 6
- Pages
- 3538-3544
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2588476563
- Cited by
- 207
- References
- 3
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.