CoChat

Development of a Liquid Chromatography–High Resolution Mass Spectrometry Metabolomics Method with High Specificity for Metabolite Identification Using All Ion Fragmentation Acquisition

Open access
Naz, Shama, Gallart-Ayala, Hector, Reinke, Stacey N., Mathon, Caroline, Blankley, Richard, Chaleckis, Romanas, Wheelock, Craig E. · 2017 · Analytical Chemistry
Cited by 143

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

High-resolution mass spectrometry (HRMS)-based metabolomics approaches have made significant advances. However, metabolite identification is still a major challenge with significant bottleneck in translating metabolomics data into biological context. In the current study, a liquid chromatography (LC)-HRMS metabolomics method was developed using an all ion fragmentation (AIF) acquisition approach. To increase the specificity in metabolite annotation, four criteria were considered: (i) accurate mass (AM), (ii) retention time (RT), (iii) MS/MS spectrum, and (iv) product/precursor ion intensity ratios. We constructed an in-house mass spectral library of 408 metabolites containing AMRT and MS/MS spectra information at four collision energies. The percent relative standard deviations between ion ratios of a metabolite in an analytical standard vs sample matrix were used as an additional metric for establishing metabolite identity. A data processing method for targeted metabolite screening was then created, merging m/z, RT, MS/MS, and ion ratio information for each of the 413 metabolites. In the data processing method, the precursor ion and product ion were considered as the quantifier and qualifier ion, respectively. We also included a scheme to distinguish coeluting isobaric compounds by selecting a specific product ion as the quantifier ion instead of the precursor ion. An advantage of the current AIF approach is the concurrent collection of full scan data, enabling identification of metabolites not included in the database. Our data acquisition strategy enables a simultaneous mixture of database-dependent targeted and nontargeted metabolomics in combination with improved accuracy in metabolite identification, increasing the quality of the biological information acquired in a metabolomics experiment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b00925

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 143

Metadata

Authors
Naz, S., Gallart-Ayala, H., Reinke, S. N., Mathon, C., Blankley, R., Chaleckis, R., & Wheelock, C. E.
Venue
Analytical Chemistry
Published
2017-07-12
Volume
89
Issue
15
Pages
7933-7942
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2640707900
Cited by
143
References
7
FWCI
5.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a Liquid Chromatography–High Resolution Mass Spectrometry Metabolomics Method with High Specificity for Metabolite Identification Using All Ion Fragmentation Acquisition. https://app.cochat.ai/papers/10.1021/acs.analchem.7b00925
The paper
Naz, S., Gallart-Ayala, H., Reinke, S. N., Mathon, C., Blankley, R., Chaleckis, R., & Wheelock, C. E. (2017). Development of a Liquid Chromatography–High Resolution Mass Spectrometry Metabolomics Method with High Specificity for Metabolite Identification Using All Ion Fragmentation Acquisition. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b00925

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.