The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cu2+-Doped SnO2 Nanograin/Polypyrrole Nanospheres with Synergic Enhanced Properties for Ultrasensitive Room-Temperature H2S Gas Sensing
Abstract
The organic–inorganic nanohybrids are emerging as one of the most attractive sensing materials in the area of gas sensors and usually exhibit some advanced properties because of synergetic/complementary effects between organic molecules and inorganic components. This work demonstrates a novel class of organic–inorganic nanohybrids, Cu 2+ -doped SnO 2 nanograin/poly pyrrole nanospheres, for the sensitive room-temperature H 2 S gas sensing. Doping Cu 2+ in SnO 2 nanograins remarkably enhances the surface potential barrier by tailoring surface defects. After polymerizing pyrrole surrounded nanograins in aqueous media to form the organic–inorganic nanohybrids, the resulting nanoheterojunctions further improve the sensitivity. Additionally, the nanohybrids-based sensor provides high surface area and abounding reaction sites to accelerate gas diffusion and adsorption as well as the electron transfer. Compare with pristine SnO 2 nanograins alone, the sensitivity of using the nanohybrids increases 7 times for the detection of 50-ppm of H 2 S. The response and recovery rate can increase 27 and 22 times at room temperature, respectively. Significantly, this work provides an attractive material for the real-time monitoring of H 2 S, whereas the insights into organic–inorganic composite interactions within the sensing mechanism may pave the way for designing functional materials with tailored properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Song, Z., Wei, Z., Wang, B., Luo, Z., Xu, S., Zhang, W., Yu, H., Li, M., Huang, Z., Zang, J., et al. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04850 · Cited by 438
Cited by
Shu, J., & Tang, D. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04199 · Cited by 976
Self-citationSemiconductor Gas Sensors: Materials, Technology, Design, and Application
Nikolic, M. V., Milovanovic, V., Vasiljevic, Z. Z., & Stamenkovic, Z. (2020) · Sensors · doi:10.3390/s20226694 · Cited by 590
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Zhang, D., Wu, Z., & Zong, X. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2019.03.055 · Cited by 264
Metadata
- Authors
- Shu, J., Qiu, Z., Lv, S., Zhang, K., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-05
- Volume
- 89
- Issue
- 20
- Pages
- 11135-11142
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2759956433
- Cited by
- 163
- References
- 1
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.