CoChat

Nonenzymatic Sensor for Lactate Detection in Human Sweat

Zaryanov, Nikolay V., Nikitina, Vita N., Karpova, Elena V., Karyakina, Elena E., Karyakin, Arkady A. · 2017 · Analytical Chemistry
Cited by 154

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

High Resolution Image Download MS PowerPoint Slide For noninvasive diagnostics of hypoxia, we propose the nonenzymatic sensor based on screen-printed structures with the working surface modified in course of electropolymerization of 3-aminophenylboronic acid (3-APBA) with imprinting of lactate. Impedimetric sensor allows lactate detection in the range from 3 mM to 100 mM with the detection limit of 1.5 mM; response time is 2–3 min. Sensor sensitivity remains unchanged within 6 months of storage unpacked in dry state at a room temperature, which is unachievable for enzyme based devices. Analysis of human sweat with poly(3-APBA) based sensor is possible due to (i) much higher lactate content compared to other polyols and (ii) high sensor selectivity ( K lactate glucose < 3 × 10 –2 ). Successful detection of lactate in human sweat by means of the poly(3-APBA) based sensor has been confirmed using the highly specific reference method based on lactate oxidase enzyme (correlation coefficient r > 0.9). The attractive performance characteristics of poly(3-APBA) based enzyme-free sensors justify their future use for noninvasive clinical analysis and sports medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.7b03662

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 154

Metadata

Authors
Zaryanov, N. V., Nikitina, V. N., Karpova, E. V., Karyakina, E. E., & Karyakin, A. A.
Venue
Analytical Chemistry
Published
2017-10-26
Volume
89
Issue
21
Pages
11198-11202
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2765968595
Cited by
154
References
2
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.