Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Microfluidic Chip-Based Wearable Colorimetric Sensor for Simple and Facile Detection of Sweat Glucose

Xiao, Jingyu, Liu, Yang, Su, Lei, Zhao, Dan, Zhao, Liang, Zhang, Xueji·2019·Analytical Chemistry

Abstract

High Resolution Image Download MS PowerPoint Slide This study reports a microfluidic chip-based wearable colorimetric sensor for detecting sweat glucose. The device consisted of five microfluidic channels branching out from the center and connected to the detection microchambers. The microchannels could route the sweat excreted from the epidermis to the microchambers, and each of them was integrated with a check valve to avoid the risk of the backflow of the chemical reagents from the microchamber. The microchambers contained the pre-embedded glucose oxidase (GOD)–peroxidase– o -dianisidine reagents for sensing the glucose in sweat. It was found that the color change caused by the enzymatic oxidation of o -dianisidine could show a more sensitive response to the glucose than that of the conventional GOD–peroxidase–KI system. This sensor could perform five parallel detections at one time. The obtained linear range for sweat glucose was 0.1–0.5 mM with a limit of detection of 0.03 mM. The sensor was also used to detect the glucose in sweat samples from a group of subjects engaged in both fasting and postprandial trials. The results showed that our wearable colorimetric sensor can reveal the subtle differences existing in the sweat glucose concentration after the fasting and the oral glucose uptake.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acs.analchem.9b03110

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 288

Metadata

Authors
Xiao, J., Liu, Y., Su, L., Zhao, D., Zhao, L., & Zhang, X.
Venue
Analytical Chemistry
Published
2019-09-25
Volume
91
Issue
23
Pages
14803-14807
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2976532365
Cited by
288
References
33
FWCI
9.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfluidic Chip-Based Wearable Colorimetric Sensor for Simple and Facile Detection of Sweat Glucose. https://app.cochat.ai/papers/10.1021/acs.analchem.9b03110
The paper
Xiao, J., Liu, Y., Su, L., Zhao, D., Zhao, L., & Zhang, X. (2019). Microfluidic Chip-Based Wearable Colorimetric Sensor for Simple and Facile Detection of Sweat Glucose. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.9b03110

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.