Ratiometric Fluorescence Sensing and Real-Time Detection of Water in Organic Solvents with One-Pot Synthesis of Ru@MIL-101(Al)–NH2
Abstract
Ratiometric fluorescence detection attracts much attention because of its decreased environmental influence and easy-to-differentiate color and intensity change. Herein, a guest-encapsulation metal–organic framework (MOF), Ru@MIL–NH 2, is prepared with 2-aminoterephthalic acid, AlCl 3, and Ru(bpy) 3 2+ by a simple one-pot method for ratiometric fluorescence sensing of water in organic solvents. The rational selection of the excitation wavelength provides dual emission at 465 and 615 nm from Ru@MIL–NH 2 under a single excitation of 300 nm. High sensitivity, low detection limit (0.02% v/v), wide response range (0–100%), and fast response (less than 1 min) are obtained for ratiometric fluorescence sensing of water under single excitation with Ru@MIL–NH 2 as the probe. Moreover, the result of water content is independent of the concentration of Ru@MIL–NH 2 as the merit of ratiometric fluorescence detection. The response mechanism reveals that the protonation of the nitrogen atom of the MIL–NH 2, the π-conjugation system, and the stable fluorescence of Ru(bpy) 3 2+ achieve the ratiometric fluorescence. The analysis of real spirit samples confirms the proposed method. A test strip is prepared with Ru@MIL–NH 2 for convenient use. We believe that such turn-on ratiometric host–guest MOFs and the rational selection of excitation wavelength will offer guidance for ratiometric fluorescence detection with wide applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
He, C., Lu, K., Liu, D., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja4098862 · Cited by 885
Cited by
Multicenter Metal–Organic Framework‐Based Ratiometric Fluorescent Sensors
Wu, S., Min, H., Shi, W., & Cheng, P. (2020) · Advanced Materials · doi:10.1002/adma.201805871 · Cited by 712
Strategies to fabricate metal–organic framework (MOF)-based luminescent sensing platforms
Liu, Y., Xie, X.-Y., Cheng, C., Shao, Z.-S., & Wang, H.-S. (2019) · Journal of Materials Chemistry C · doi:10.1039/c9tc03208h · Cited by 400
Gutiérrez, M., Zhang, Y., & Tan, J.-C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00980 · Cited by 351
Shu, Y., Ye, Q., Dai, T., Xu, Q., & Hu, X. (2021) · ACS Sensors · doi:10.1021/acssensors.0c02562 · Cited by 326
Metadata
- Authors
- Yin, H.-Q., Yang, J.-C., & Yin, X.-B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-11-30
- Volume
- 89
- Issue
- 24
- Pages
- 13434-13440
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2770836641
- Cited by
- 231
- References
- 1
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ratiometric Fluorescence Sensing and Real-Time Detection of Water in Organic Solvents with One-Pot Synthesis of Ru@MIL-101(Al)–NH2. https://app.cochat.ai/papers/10.1021/acs.analchem.7b03723
- The paper
- Yin, H.-Q., Yang, J.-C., & Yin, X.-B. (2017). Ratiometric Fluorescence Sensing and Real-Time Detection of Water in Organic Solvents with One-Pot Synthesis of Ru@MIL-101(Al)–NH2. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.7b03723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.