3D-Printed Microflow Injection Analysis Platform for Online Magnetic Nanoparticle Sorptive Extraction of Antimicrobials in Biological Specimens as a Front End to Liquid Chromatographic Assays
Abstract
In this work, the concept of 3D-printed microflow injection (3D-μFI) embodying a dedicated multifunctional 3D-printed stator onto a rotary microvalve along with a mesofluidic sample preparation platform is proposed for the first time. A transparent 3D-printed stereolithographic mesofluidic chip device accommodating polyaniline (PANI) decorated magnetic nanoparticles (32.5 ± 3.8 mg) is harnessed to in-line sorptive microextraction as a front end to liquid chromatography with peak focusing. As a proof-of-concept application, the 3D-μFI assembly was resorted to matrix cleanup and automatic programmable-flow determination of organic emerging contaminants (4-hydroxybenzoate analogues and triclosan as antimicrobial model analytes) in human saliva and urine samples. By using a sample volume of 1.0 mL with a loading flow rate of 200 μL min -1 , an eluent volume of 120 μL at 80 μL min -1 , and online HPLC injection of 300 μL of the mixture of eluate and Milli-Q water (in a 1:2 ratio) to prevent band broadening effects of the most polar analytes, the limits of detection (3σ criterion) ranged from 1.1 to 4.5 ng mL -1 for methylparaben (MP), ethylparaben (EP), propylparaben (PrP), phenylparaben (PhP), butylparaben (BP), and triclosan (TCS). Enhancement factors of 16-25 were obtained for the target analytes. Spike recoveries ranged from 84 to 117% for both saliva and urine samples. The online 3D-μFI hyphenated method is synchronized with the chromatographic separation and features a chip…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Different applications of 3D printing to fabricate devices for solid-phase extraction have been reported.
“In the fi eld of sample preparation, di ff erent applications of 3D printing to fabricate devices for solid-phase extraction have been reported [41 -47].”
From Automated dispersive liquid-liquid microextraction based on the solidification of the organic phase (2018) · cites this paper as [43]
In comparison with magnetic solid-phase extraction of parabens using a 3D printed micro-flow injection setup, similar LODs and EFs were obtained.
“In comparison with the magnetic solidphase extraction of parabens using a 3D printed micro- fl ow injection set up [43], also similar LODs and EFs were obtained.”
From Automated dispersive liquid-liquid microextraction based on the solidification of the organic phase (2018) · cites this paper as [43]
Cites
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039 · see citing works
Comparing Microfluidic Performance of Three-Dimensional (3D) Printing Platforms
Macdonald, N. P., Cabot, J. M., Smejkal, P., Guijt, R. M., Paull, B., & Breadmore, M. C. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00136 · Cited by 425 · see citing works
Ocaña-González, J. A., Villar-Navarro, M., Ramos-Payán, M., Fernández-Torres, R., & Bello-López, M. A. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.07.002 · Cited by 129 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Automated dispersive liquid-liquid microextraction based on the solidification of the organic phase
Medina, D. A. V., Santos-Neto, Á. J., Cerdà, V., & Maya, F. (2018) · Talanta · doi:10.1016/j.talanta.2018.06.081 · Cited by 55 · see citing works
Díaz-Álvarez, M., Turiel, E., & Martín-Esteban, A. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343617 · Cited by 16 · see citing works
- Authors
- Wang, H., Cocovi-Solberg, D. J., Hu, B., & Miró, M.
- Affiliations
- Wuhan University (CN)
- Universitat de les Illes Balears (ES)
- Corresponding author
- Hu, Bin
- Miró, Manuel
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-10-31
- Volume
- 89
- Issue
- 22
- Pages
- 12541-12549
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2766562419
- Cited by
- 59
- References
- 3
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 5 · 2023: 4 · 2022: 6 · 2021: 10 · 2020: 9 · 2019: 6 · 2018: 9
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Regional Development Fund (CTM2014-56628-C3-3-R, CTM2014-61553-EXP)
- Secretar?a de Estado de Investigaci?n, Desarrollo e Innovaci?n (CTM2014-56628-C3-3-R, CTM2014-61553-EXP)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Keywords
- emerging contaminants, methylparaben, ethylparaben, propylparaben, butylparaben, triclosan, antimicrobial agents, saliva, urine, liquid chromatography, 3D printing
- MeSH terms
- Adsorption, Anti-Infective Agents, Chromatography, Liquid, Humans, Parabens, Surface Properties, Triclosan, Flow Injection Analysis, Magnetite Nanoparticles, Printing, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.