The DOI matches its Crossref record.
Rotational Paper-Based Microfluidic-Chip Device for Multiplexed and Simultaneous Fluorescence Detection of Phenolic Pollutants Based on a Molecular-Imprinting Technique
Abstract
In this study, we first present rotational paper-based microfluidic chips (RPADs) combined with a molecular-imprinting (MIP) technique to detect phenolic pollutants. The proposed rotational paper-based microfluidic chips could implement qualitative and quantitative analysis of two different phenolic contaminants, 4-nitrophenol (4-NP) and 2,4,6-trinitrophenol (TNP), simultaneously. Qualitative and quantitative analysis could be implemented simultaneously through fluorescence-intensity changes depending on the structures of quantum dots combined with a molecular-imprinting technique. Moreover, the rotational paper-based microfluidic chips provide a low cost, flexible, and easy way to operate the entire process conveniently. Under the optimal conditions, the proposed sensors showed high sensitivity and selectivity. Our final experimental results illustrated that the detection limits of 4-NP and TNP in the paper-based quantum-dot MIP (PQ-MIP) RPADs ranged from 0.5 to 20.0 mg/L, with detection limits of 0.097 and 0.071 mg/L, respectively. This novel rotational paper-based microfluidic device shows great potential and versatility for multiplexed, portable, and rapid testing of environmental and biological samples in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Wang, H., Yang, L., Chu, S., Liu, B., Zhang, Q., Zou, L., Yu, S., & Jiang, C. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02297 · Cited by 400
Chen, Z., Zhang, Z., Qi, J., You, J., Ma, J., & Chen, L. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129889 · Cited by 319
Self-citationSensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Metadata
- Authors
- Qi, J., Li, B., Wang, X., Fu, L., Luo, L., & Chen, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-08-23
- Volume
- 90
- Issue
- 20
- Pages
- 11827-11834
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2888027624
- Cited by
- 183
- References
- 0
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rotational Paper-Based Microfluidic-Chip Device for Multiplexed and Simultaneous Fluorescence Detection of Phenolic Pollutants Based on a Molecular-Imprinting Technique. https://app.cochat.ai/papers/10.1021/acs.analchem.8b01291
- The paper
- Qi, J., Li, B., Wang, X., Fu, L., Luo, L., & Chen, L. (2018). Rotational Paper-Based Microfluidic-Chip Device for Multiplexed and Simultaneous Fluorescence Detection of Phenolic Pollutants Based on a Molecular-Imprinting Technique. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.8b01291
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.